Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/27137
Título: Rapid and sensitive methodology for determination of ethyl carbamate in fortified wines using microextraction by packed sorbent and gas chromatography with mass spectrometric detection
Autor: Leça, João M. 
Pereira, Vanda 
Pereira, Ana C. 
Marques, José C. 
Palavras-chave: Ethyl carbamate; Wines; Microextraction by packed sorbent; Gas chromatography–mass spectrometric detection
Data: 6-Fev-2014
Editora: Elsevier
Citação: LEÇA, João M. [et al.] - Rapid and sensitive methodology for determination of ethyl carbamate in fortified wines using microextraction by packed sorbent and gas chromatography with mass spectrometric detection. "Analytica Chimica Acta". ISSN 0003-2670. Vol. 811 (2014) p. 29-35
Título da revista, periódico, livro ou evento: Analytica Chimica Acta
Volume: 811
Resumo: This work presents a new methodology to quantify ethyl carbamate (EC) in fortified wines. The presented approach combines the microextraction by packed sorbent (MEPS), using a hand-held automated analytical syringe, with one-dimensional gas chromatography coupled with mass spectrometry detection (GC–MS). The performance of different MEPS sorbent materials was tested, namely SIL, C2, C8, C18, and M1. Also, several extraction solvents and the matrix effect were evaluated. Experimental data showed that C8 and dichloromethane were the best sorbent/solvent pair to extract EC. Concerning solvent and sample volumes optimization used in MEPS extraction an experimental design (DoE) was carried out. The best extraction yield was achieved passing 300 μL of sample and 100 μL of dichloromethane. The method validation was performed using a matrix-matched calibration using both sweet and dry fortified wines, to minimize the matrix effect. The proposed methodology presented good linearity (R2 = 0.9999) and high sensitivity, with quite low limits of detection (LOD) and quantification (LOQ), 1.5 μg L−1 and 4.5 μg L−1, respectively. The recoveries varied between 97% and 106%, while the method precision (repeatability and reproducibility) was lower than 7%. The applicability of the methodology was confirmed through the analysis of 16 fortified wines, with values ranging between 7.3 and 206 μg L−1. All chromatograms showed good peak resolution, confirming its selectivity. The developed MEPS/GC–MS methodology arises as an important tool to quantify EC in fortified wines, combining efficiency and effectiveness, with simpler, faster and affordable analytical procedures that provide great sensitivity without using sophisticated and expensive equipment.
URI: https://hdl.handle.net/10316/27137
ISSN: 0003-2670
DOI: 10.1016/j.aca.2013.12.018
Direitos: openAccess
Aparece nas coleções:I&D CIEPQPF - Artigos em Revistas Internacionais
FCTUC Eng.Química - Artigos em Revistas Internacionais

Ficheiros deste registo:
Mostrar registo em formato completo

Citações SCOPUSTM   

42
Visto em 13/mai/2024

Citações WEB OF SCIENCETM
5

37
Visto em 2/mar/2024

Visualizações de página

342
Visto em 7/mai/2024

Downloads 10

1.708
Visto em 7/mai/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.