Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10316/21650
Título: | In vitro and in vivo evaluation of an intraocular implant for glaucoma treatment | Autor: | Natu, Mădălina V. Gaspar, Manuel N. Ribeiro, Carlos A. Fontes Cabrita, António M. Sousa, Hermínio C. de Gil, M. H. |
Palavras-chave: | Poly(ɛ-caprolactone); Subconjunctival implant; Controlled drug release; In vivo; Intraocular pressure; Glaucoma | Data: | Jul-2011 | Editora: | Elsevier | Citação: | NATU, Mădălina V. [et al.] - In vitro and in vivo evaluation of an intraocular implant for glaucoma treatment. "International Journal of Pharmaceutics". ISSN 0378-5173. 415:1–2 (2011) 73-82 | Título da revista, periódico, livro ou evento: | International Journal of Pharmaceutics | Volume: | 415 | Número: | 1-2 | Resumo: | Implantable disks for glaucoma treatment were prepared by blending poly(ɛ-caprolactone), PCL, poly(ethylene oxide)-b-poly(propylene oxide)-b-poly(ethylene oxide) and dorzolamide. Their in vivo performance was assessed by their capacity to decrease intraocular pressure (IOP) in normotensive and hypertensive eyes. Drug mapping showed that release was complete from blend disks and the low molecular weight (MW) PCL after 1 month in vivo. The high MW PCL showed non-cumulative release rates above the therapeutic level during 3 months in vitro. In vivo, the fibrous capsule formation around the implant controls the drug release, working as a barrier membrane. Histologic analysis showed normal foreign body reaction response to the implants. In normotensive eyes, a 20% decrease in IOP obtained with the disks during 1 month was similar to Trusopt® eyedrops treatment. In hypertensive eyes, the most sustained decrease was shown by the high MW PCL (40% after 1 month, 30% after 2 months). It was shown that the implants can lower IOP in sustained manner in a rabbit glaucoma model. | URI: | https://hdl.handle.net/10316/21650 | ISSN: | 0378-5173 | DOI: | 10.1016/j.ijpharm.2011.05.047 | Direitos: | openAccess |
Aparece nas coleções: | FCTUC Eng.Química - Artigos em Revistas Internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
In vitro and in vivo evaluation of an intraocular implant for glaucoma treatment.pdf | 1.32 MB | Adobe PDF | Ver/Abrir |
Citações SCOPUSTM
27
Visto em 9/set/2024
Citações WEB OF SCIENCETM
5
27
Visto em 2/jul/2024
Visualizações de página
370
Visto em 10/set/2024
Downloads 20
873
Visto em 10/set/2024
Google ScholarTM
Verificar
Altmetric
Altmetric
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.