dc.description.abstractEm Portugal, o setor dos edifícios representa quase 30% dos consumos totais de energia, sendo que 12% diz respeito a edifícios de serviços. No ano de 2016, a maior parte dos certificados energéticos emitidos para este tipo de edifícios indicavam a classificação de C, (Bernardo, 2015; INE e DGEG, 2011; ADENE, 2016b). O elevado potencial de poupança energética neste tipo de edifícios incentiva a implementação de medidas de melhoria de eficiência energética, quer relacionadas com os elementos passivos do edifício quer com os seus sistemas ativos quer, ainda, com os sistemas e procedimentos de gestão de energia, O trabalho aqui apresentado tem como principal objetivo a identificação de oportunidades de melhoria de eficiência energética das agências de uma dada Instituição Bancária. O mesmo decorreu sob a forma de estágio inserido na equipa de gestão de energia da empresa Virtual Power Solutions, num projeto já em execução pela mesma. Dado envolver dezenas de agências com áreas destintas, os consumos de cada uma foram normalizados recorrendo ao indicador consumo específico de energia (kWh/m2).A análise dos consumos para os sistemas de AVAC (Aquecimento, Ventilação e Ar Condicionado) foi efetuado em separado para períodos de inverno e de verão, sendo posteriormente subdividido por zonas climáticas das respetivas agências. Foi possível concluir que o consumo médio de energia pelo AVAC é mais crítico no período de verão. Os consumos específicos de energia pela iluminação apresentam uma grande dispersão de valores, causada por algumas agências cujo o consumo específico de energia respeitante à iluminação é muito elevado. Visitaram-se algumas das agências com maior consumo específico de energia, para as quais são propostas medidas de melhoria. Estas apresentam payback simples com valores que variam entre 1 e 2 anos.Foi também realizado uma pequena análise a outros tipos de equipamentos existentes nas agências. Foi identificado uma grande percentagem de consumo de energia de equipamentos em standby, havendo também aí um grande potencial de poupança energética.De modo a gerar poupanças a curto prazo, foi levado a cabo um plano de deslastre de cargas dos sistemas de AVAC. Assim, foi possível realizar algumas análises, tais como a influência da zona climática nas poupanças de energia conseguidas.por
dc.description.abstractIn Portugal, the buildings sector accounts for almost 30% of total energy consumption, of which 12% refers to service buildings. In 2016, most of the energy certificates issued for this type of buildings indicated the classification of C. The high potential of energy saving in this type of buildings encourages the implementation of energy efficiency improvement measures, whether related to the passive elements of the building either with its active systems or with energy management systems and procedures.The main objective of the work is to identify opportunities for improving the energy efficiency of the agencies of a given Banking Institution. The same happened in the form of internship inserted in the energy manager team of Virtual Power Solutions. As it involved dozens of agencies with designated areas, the consumption of each was normalized using a specific energy consumption indicator (kWh/m2).An analysis of the HVAC systems (Heating, Ventilation and Air Conditioning) was carried out separately for winter and summer periods, being subdivided by climatic zones of the respective agencies. It was possible to conclude that the average of specific consumption by the HVAC is more critical in the summer period.The specific consumption of energy by illumination presents a great dispersion of values, caused by some agencies whose specific consumption of energy regarding the illumination is very high. We visited some of the agencies with the highest specific energy consumption, for which improvement measures are proposed. These have simple payback values ranging from 1 to 2 years.A small analysis was also done on other types of equipment in the agencies. A large percentage of the energy consumption of standby equipment has been identified. There is also a great potential for energy savings.In order to generate savings in the short term, a load shedding plan of the HVAC systems was carried out. Thus, it was possible to perform some analysis, such as the influence of the climatic zone on the energy savings achieved.eng
dc.language.isopor-
dc.rightsopenAccess-
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.subjectGestão energética em edifícios de serviçospor
dc.subjectAgências Bancáriaspor
dc.subjectMonitorização de energiapor
dc.subjectConsumos de energia em sistemas de AVACpor
dc.subjectConsumos de energia em sistemas de iluminaçãopor
dc.subjectEnergy management in service buildingseng
dc.subjectBank agencies Energy monitoringeng
dc.subjectEnergy consumption in HVAC systemseng
dc.subjectEnergy consumption in lighting systemseng
dc.subjectLoad shedding in HVAC systemseng
dc.titleGestão energética em Edifícios de Serviços - Sector da Bancapor
dc.title.alternativeEnergy Management in Services Building - Banking Sectoreng
dc.typemasterThesis-
degois.publication.locationDepartamento de Engenharia Mecânica-
degois.publication.titleGestão energética em Edifícios de Serviços - Sector da Bancapor
dc.peerreviewedyes-
dc.identifier.tid202126188-
thesis.degree.disciplineEngenharia Mecânica-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado Integrado em Engenharia Mecânica-
uc.degree.grantorUnitFaculdade de Ciências e Tecnologia - Departamento de Engenharia Mecânica-
uc.degree.grantorID0500-
uc.contributor.authorLopes, Tiago Filipe Estanqueiro::0000-0002-2361-7690-
uc.degree.classification17-
uc.degree.presidentejuriGaspar, Adélio Manuel Rodrigues-
uc.degree.elementojuriSimões, Ana Cecília Rodrigues Guimarães-
uc.degree.elementojuriBrites, Gonçalo Jorge Vieira Nunes-
uc.contributor.advisorSimões, Ana Cecília Rodrigues Guimarães-
uc.contributor.advisorRaimundo, António Manuel Mendes-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.languageiso639-1pt-
item.openairetypemasterThesis-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextCom Texto completo-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
File Description SizeFormat
Dissertacao - versão corrigida.pdf1.89 MBAdobe PDFView/Open
Show simple item record

Page view(s) 50

456
checked on May 7, 2024

Download(s) 50

605
checked on May 7, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons