Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/83227
Title: Measurement of ion mobility in relevant mixtures used in gas detectors
Other Titles: Mobilidade de iões em misturas gasosas utilizadas em detetores de radiação
Authors: Perdigoto, José Manuel Carvalheiro 
Orientador: Soares, Filipa Isabel Gouveia de Melo Borges Belo
Keywords: Transporte de cargas e multiplicação em gases; Fontes de iões (iões positivos, iões negativos); Detetores gasosos; Processos de ionização e excitação; Mobillidade de iões; Charge transport and multiplication in gases; Ion sources (positive ions, negative ions); Gaseous detectors; Ionization and excitation processes; Ion mobility
Issue Date: 29-Sep-2017
Serial title, monograph or event: Measurement of ion mobility in relevant mixtures used in gas detectors
Place of publication or event: DF-UC
Abstract: Os TRD (Detetores de Radiação de Transição) são maioritariamente usados na identi cação de particulas a elevado momento. Nesta base, a escolha da mistura gasosa para tais detetores é determinada por certos parâmetros, tais como elevada velocidade de eletrões/iões e baixa difusão de eletrões, os quais são de extrema importância já que influencía a rate capability e a formação de sinal de detetores como as Câmaras Proporcionais de multi- fios (MWPCs).No contexto da nossa participação na colaboração RD51/CERN, foi estabelecido um projeto comum com a GSI Darmstag (Alemanha), Universidade de Uludag (Turquia) e VECC (India) que se focou no estudo de propriedades de transporte de iões de misturas gasosas relevantes para o ALICE TPC. Tendo isso como foco, foram efetuadas medidas experimentais de mobilidade de iões, K0, para várias misturas gasosas, nomeadamente para misturas de Xenon (Xe-C2H6 and Xe-CH4) e misturas de azoto (Ar-N2). Os resultados são apresentados para pressões totais de 8 Torr e campos elétricos reduzidos (E/N) compreendidos entre 10-25 Td, à temperatura ambiente.A IDC (Ion Drift Chamber) usada para efetuar os estudos de mobilidade de iões foi inicialmente desenvolvida por P.N.B. Neves. As técnicas para a realização dos estudos anteriormente mencionados são descritas neste documento e fazem uso de um GEM (Gaseous Electron Multiplier) e uma lâmpada de flash UV para produzir os iões.Os resultados relativos a misturas de C2H6 revelam a presença de dois picos ao longo de todo o estudo efetuado, para além do aparecimento de um pequeno pico à direita do pico principal para concentrações de Xe superiores a 70% e campos reduzidos de 20Td. Já para misturas de CH4 é reportado a presença de dois grupos distintos de iões,em que a natureza dos mesmos depende do rácio da mistura, já que estes são originados tanto por Xe como por CH4.
Transition Radiation Detectors (TRDs) are mainly used for particle identi cation at high momenta. Moreover, the choice of the gas mixture for such detectors is determined by several parameters such as high electron/ion velocity and low electron diffusion, which are of key importance as they influence the rate capability and signal formation of detectors such as the Multi-Wire Proportional Chambers (MWPCs).In the span of our participation in the RD51 collaboration/CERN, a common project was established with GSI Darmstag (Germany), Uludag University (Turkey) and VECC (India) regarding the study of ion transport properties of relevant gas mixtures for ALICE TPC. With this in mind, we performed experimental ion mobility measurements, K0, for several gas mixtures, namely xenon mixtures (Xe-C2H6 and Xe-CH4) and nitrogen mixtures (Ar-N2). The results are presented for total pressures ranging from 6-10 Torr and for reduced electric fields (E/N) in the 10-25 Td range at room temperature.The IDC (Ion Drift Chamber) used to conduct the ion mobility studies was initially developed by P. N. B. Neves. The techniques to perform the aforementioned studies are described in this report and make used of a Gaseous Electron Multiplier (GEM)and a UV flash lamp to produce the ions.The results for the C2H6 mixtures show the presence of two peaks throughout the entire range studied, besides the appearance of a small bump at the right side of the main peak for concentrations of Xe higher than 70% and reduced electric fields higher than 20Td. While for the CH4 mixtures it is reported the presence of two distinct groups of ions, with their nature depending on the mixture ratio since they are originated by both Xe and CH4.
Description: Dissertação de Mestrado Integrado em Engenharia Física apresentada à Faculdade de Ciências e Tecnologia
URI: https://hdl.handle.net/10316/83227
Rights: openAccess
Appears in Collections:UC - Dissertações de Mestrado

Files in This Item:
File Description SizeFormat
Dissertação_José Manuel Carvalheiro Perdigoto_2017.pdf10.08 MBAdobe PDFView/Open
Show full item record

Page view(s) 50

484
checked on Jul 17, 2024

Download(s) 50

540
checked on Jul 17, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons