Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/38500
DC FieldValueLanguage
dc.contributor.advisorMendes, Paulo Jorge Rodrigues Amado-
dc.contributor.advisorSimões, Nuno Albino Vieira-
dc.contributor.authorMartins, Filipa Claudia Abrantes-
dc.date.accessioned2017-03-27T10:03:06Z-
dc.date.available2017-03-27T10:03:06Z-
dc.date.issued2013-09-06por
dc.identifier.urihttps://hdl.handle.net/10316/38500-
dc.descriptionDissertação de Mestrado Integrado em Engenharia Civil apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbrapor
dc.description.abstractAo longo dos anos a exigência em relação à envolvente dos edifícios tem vindo a aumentar, devido aos níveis de conforto mais elevados que a sociedade tem vindo a requerer. Devido à necessidade de proteção do ambiente interior do ruído exterior, de qualidade do ambiente interior e de redução de consumo de energia, enquadra-se a importância do estudo da relação entre comportamento acústico e permeabilidade ao ar da envolvente de edifícios. Na prossecução do objetivo definido foi efetuada a revisão bibliográfica de estudos pertinentes para o trabalho realizado. Foram estudados dois métodos de ensaio: o ensaio de pressurização, com recurso ao equipamento Blower Door de acordo com a norma NP 13829:2000 [1], e ensaios in situ de avaliação do isolamento sonoro a sons de condução aérea da fachada, de acordo com a norma NP ISO 140-5:2009 [2]. Foram selecionados e analisados compartimentos e edifícios onde se utilizaram os métodos de ensaio previamente estudados. A seleção dos edifícios foi realizada de forma a tentar permitir os dois ensaios no mesmo edifício. Para os edifícios selecionados, foi realizada a caracterização, compilação de dados e, nalguns casos, obtenção de resultados adicionais. A partir da análise dos dados recolhidos tentou analisar-se a relação do comportamento acústico, da permeabilidade ao ar, e das características dos edifícios.por
dc.description.abstractOver the years the requirements for the building envelope has been increasing due to higher levels of comfort according to society’s needs. It was due to the aim of protecting the indoor environment from the outside noise, indoor environmental quality and reduce energy consumption, that the study of the relationship between the acoustic behavior and air permeability of the buildings envelope aroused. In order to attain the objective of this study a review of studies, relevant to the theme of the work performed, was carried out. Two test methods were studied: the pressurization test, using the pressurization equipment Blower Door according to NP 13829:2000 [1], and measurements of airborne sound insulation of façades, according to EN ISO 140-5:2009 [2]. The buildings were selected so that both tests, mentioned above, were applied in the same building. For the selected buildings a characterization and compilation of data were developed, and additional results were obtained. From the analysis of the collected data and evaluated results the relationship between acoustic behavior, air permeability, and the characteristics of the buildings was studied and analyzedeng
dc.language.isoporpor
dc.rightsopenAccesspor
dc.subjectpermeabilidade ao ar de fachadaspor
dc.subjectisolamento sonoro a sons aéreospor
dc.subjectenvidraçadospor
dc.subjectair permeability of façadespor
dc.subjectairborne sound insulationpor
dc.subjectglazing areapor
dc.titleContributo para análise da relação entre comportamento acústico e permeabilidade ao ar da envolvente de edifíciospor
dc.typemasterThesispor
degois.publication.locationCoimbrapor
dc.identifier.tid201658232por
thesis.degree.grantorUniversidade de Coimbrapor
thesis.degree.nameMestrado Integrado em Engenharia Civilpor
uc.degree.grantorUnit0501 - Faculdade de Ciências e Tecnologiapor
uc.controloAutoridadeSim-
item.openairetypemasterThesis-
item.fulltextCom Texto completo-
item.languageiso639-1pt-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.advisor.researchunitCentre for Research in Construction Science-
crisitem.advisor.researchunitCentre for Research in Construction Science-
crisitem.advisor.orcid0000-0003-2233-2383-
crisitem.advisor.orcid0000-0003-3418-0030-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Civil - Teses de Mestrado
Show simple item record

Page view(s)

343
checked on Jul 16, 2024

Download(s)

287
checked on Jul 16, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.