Title: Microtensile dentin bond strength evaluation of different adhesive systems: in vitro study
Authors: Campos, Sandra Filipa Seabra de 
Orientador: Ramos, João Carlos
Marques, Fernando
Keywords: Microtensile; Dentin bond strength; Etch-and-rinse; Self-etch; Dentin adhesion
Issue Date: 2013
Abstract: Introduction: Modern restorative dentistry has been extensively influenced by the fast progress in dental adhesive technology. To assess the effectiveness of adhesive systems and to predict their clinical performance the resin-dentin bond strength tests has been widely used. Purpose: The goal of this study was to compare the microtensile bond strength of five different adhesives systems at the dentin-composite interface and evaluate failure modes. Materials and methods: Flat dentin surfaces were prepared in 25 non-carious human molars. Exposed dentin surfaces were wet-grounded with 240-, 400- and 600-grit silicon-carbide sandpaper to create bonding surfaces with a standardized smear layer. The teeth were randomly divided into 5 distinct groups according to the adhesive system tested: three self-etching adhesive systems, Xeno® V+ (Dentsply DeTrey, Konstanz, Germany); Xeno® III (Dentsply DeTrey, Konstanz, Germany) and ClearfilTM SE Bond (Kuraray Medical Inc., Okayama, Japan), and two etch-and-rinse adhesive systems, OptiBondTM FL (Kerr, Orange, CA, USA) and Prime&Bond® NT (Dentsply DeTrey, Konstanz, Germany) applied with respect to manufacturer’s instructions. After adhesive procedures a 4-mm thick composite crown was built over the bonded surface. Following the storage in distilled water at 37 ºC, the samples were vertically cross-sectioned until obtaining sticks with 1.37mm2 of cross-sectional area which were tested in tension in a universal testing machine at 0.5 mm/min. Data were analyzed by one-away ANOVA and a Tukey HSD post-hoc test (p<0.05). The mode of failure was also analysed with optical microscopy. Additionally, dentin disks were obtained, treated with the different conditioners and primers and observed by scanning electron microscopy (SEM). Results: The following microtensile bond strengths were registered (mean in MPa±SD): Group I – Xeno® V+ 3.70±5.01; Group II - Xeno® III 18.94±13.87; Group III – OptiBondTM FL 43.29±12.74; Group IV- Prime&Bond® NT 39.64±15.06 and Group V – ClearfilTM SE Bond 42.80±10.65. Etch-and-rinse (OptiBondTM FL; Prime & Bond® NT) and two-step self-etching (ClearfilTM SE Bond) adhesive systems attained significant higher microtensile bond strength, without statistically significant differences between them. Significant lower values were obtained for Xeno® V+ comparing to Xeno® III. Cohesive composite failures were related with the higher bond strength values, whereas the adhesive failures were associated with the lowest bond strength values. Conclusion: Among the materials evaluated, etch-and-rinse and two-step self-etching adhesive systems presented higher dentin bond strength than the one-step self-etching adhesive systems.
Description: Trabalho final do 5º ano com vista à atribuição do grau de mestre no âmbito do ciclo de estudos de Mestrado Integrado em Medicina Dentária apresentado à Faculdade de Medicina da Universidade de Coimbra.
URI: https://hdl.handle.net/10316/36208
Rights: openAccess
Appears in Collections:UC - Dissertações de Mestrado
FMUC Med. Dentária - Teses de Mestrado

Files in This Item:
File Description SizeFormat
TESE - Sandra Campos.pdfTESE - Sandra Campos832.45 kBAdobe PDFView/Open
Show full item record

Page view(s)

210
checked on Mar 26, 2024

Download(s)

121
checked on Mar 26, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.