Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/27828
Título: Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements
Autor: Attar, Aisha 
Ghica, M. Emilia 
Amine, Aziz 
Brett, Christopher M. A. 
Palavras-chave: Amperometric biosensor; Horseradish peroxidase; Poly(neutral red); Cr(III); Cr(VI); Enzyme inhibition
Data: 30-Ago-2014
Editora: Elsevier
Citação: ATTAR, Aisha [et. al] - Poly(neutral red) based hydrogen peroxide biosensor for chromium determination by inhibition measurements. "Journal of Hazardous Materials". ISSN 0304-3894. Vol. 279 (2014) p. 348–355
Projeto: info:eu-repo/grantAgreement/EC/FP7/230815/EU 
Título da revista, periódico, livro ou evento: Journal of Hazardous Materials
Volume: 279
Resumo: Amperometric hydrogen peroxide enzyme inhibition biosensors based on horseradish peroxidase (HRP) immobilised on electropolymerised neutral red (NR) or directly on the surface of carbon film electrodes (CFE) have been successfully applied to the determination of toxic Cr(III) and Cr(VI). Parameters influencing the performance of the biosensor including the enzyme immobilisation method, the amount of hydrogen peroxide, applied potential and electrolyte pH were optimised. The inhibition of horseradish peroxidase by the chromium species was studied under the optimised conditions. Results from the quantitative analysis of chromium ions are discussed in terms of detection limit, linear range and sensitivity. The HRP kinetic interactions reveal mixed binding of Cr(III) with I50 = 3.8 μM and inhibition binding constant Ki = 11.3 μM at HRP/PNR/CFE biosensors and uncompetitive binding of Cr(VI) with I50 = 3.9 μM and Ki = 0.78 μM at HRP/CFE biosensors in the presence of H2O2 substrate. Interferences from other heavy metal ions were studied and the inhibition show very good selectivity towards Cr(III) and Cr(VI).
URI: https://hdl.handle.net/10316/27828
ISSN: 0304-3894
DOI: 10.1016/j.jhazmat.2014.07.019
Direitos: openAccess
Aparece nas coleções:FCTUC Química - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
Poly(neutral red) based hydrogen peroxide biosensor.pdf656.98 kBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações SCOPUSTM   

41
Visto em 1/mai/2023

Citações WEB OF SCIENCETM
5

43
Visto em 2/fev/2024

Visualizações de página 50

459
Visto em 23/abr/2024

Downloads 50

451
Visto em 23/abr/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.