Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/113750
Title: Valorization of brewer’s spent grain by furfural recovery/removal from subcritical water hydrolysates by pervaporation
Authors: Alonso-Riaño, Patricia
Illera, Alba E.
Amândio, Mariana 
Xavier, Ana M.R.B.
Beltrán, Sagrario
Teresa Sanz, M.
Keywords: Brewer’s spent grain; Subcritical water hydrolysates; Pervaporation; PDMS/POMS membranes; Furfural
Issue Date: 2023
Publisher: Elsevier
Project: This work was supported by the Agencia Estatal de Investigaci´on [Grants No PID2019-104950RB-I00 / AEI / 10.13039/501100011033, TED2021-129311B-I00 and PDC2022-133443-I00] and the Junta de Castilla y Le´on (JCyL) and the European Regional Development Fund (ERDF) [grant number BU050P20]. P. Alonso-Ria˜no predoctoral contract was funded by JCyL and the European Social Fund (ESF) by ORDEN EDU/556/2019 de 5 de junio. 
UIDB/50011/2020 
UIDP/50011/2020 
LA/P/0006/2020 
Serial title, monograph or event: Separation and Purification Technology
Volume: 309
Abstract: This work is focused on the development of a sustainable process for the valorisation of the main by-product generated in the brewing industry, the brewer’s spent grain (BSG). A two-step process combining subcritical water treatment and pervaporation (PV) was proposed to hydrolyse the hemicelluloses fraction of this lignocellulosic biomass and further removal/recovery of some of the degradation products of sugars by using two different organophilic membranes, polydimethylsiloxane (PDMS) and polyoctilmethylsiloxane (POMS) membranes. Specifically, furfural is the dehydration product of pentoses and it is one of the top biomass-based chemicals being an important platform chemical. For synthetic binary mixtures, lower total permeation flux but higher enrichment factors for furfural were determined for POMS. When dealing with subW hydrolysates, POMS membranes yielded the highest furfural recovery, 94.1 %, with permeate concentrations as high as 40 g⋅L- 1. Furthermore, it was assessed that PV is a suitable detoxification method that yielded a retentate nearly free of furfural allowing its use as growth media in the opposite to the subW hydrolysate with inhibitory furfural concentrations for microbial bioprocesses.
URI: https://hdl.handle.net/10316/113750
ISSN: 13835866
DOI: 10.1016/j.seppur.2022.123008
Rights: openAccess
Appears in Collections:FCTUC Eng.Química - Artigos em Revistas Internacionais
I&D CIEPQPF - Artigos em Revistas Internacionais

Show full item record

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons