Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/113135
DC FieldValueLanguage
dc.contributor.authorGabriel, Cristiana Lopes-
dc.contributor.authorPires, Ivan Miguel-
dc.contributor.authorCoelho, Paulo Jorge-
dc.contributor.authorZdravevski, Eftim-
dc.contributor.authorLameski, Petre-
dc.contributor.authorMewada, Hiren-
dc.contributor.authorMadeira, Filipe-
dc.contributor.authorGarcia, Nuno M.-
dc.contributor.authorCarreto, Carlos-
dc.date.accessioned2024-02-06T12:13:27Z-
dc.date.available2024-02-06T12:13:27Z-
dc.date.issued2023-06-
dc.identifier.issn2405-8440pt
dc.identifier.urihttps://hdl.handle.net/10316/113135-
dc.description.abstractPhysical issues started to receive more attention due to the sedentary lifestyle prevalent in modern culture. The Ten Meter Walk Test allows measuring the person's capacity to walk along 10 m and analyzing the advancement of various medical procedures for ailments, including stroke. This systematic review is related to the use of mobile or wearable devices to measure physical parameters while administering the Ten Meter Walk Test for the analysis of the performance of the test. We applied the PRISMA methodology for searching the papers related to the Ten Meter Walk Test. Natural Language Processing (NLP) algorithms were used to automate the screening process. Various papers published in two decades from multiple scientific databases, including IEEE Xplore, Elsevier, Springer, EMBASE, SCOPUS, Multidisciplinary Digital Publishing Institute (MDPI), and PubMed Central were analyzed, focusing on various diseases, devices, features, and methods. The study reveals that chronometer and accelerometer sensors measuring spatiotemporal features are the most pertinent in the Gait characterization of most diseases. Likewise, all studies emphasized the close relation between the quality of the sensor's data obtained and the system's ultimate accuracy. In other words, calibration procedures are needed because of the body part where the sensor is worn and the type of sensor. In addition, using ambient sensors providing kinematic and kinetic features in conjunction with wearable sensors and consistently acquiring walking signals can enhance the system's performance. The most common weaknesses in the analyzed studies are the sample size and the unavailability of continuous monitoring devices for measuring the Ten Meter Walk Test.pt
dc.language.isoengpt
dc.publisherElsevierpt
dc.relationUIDB/50008/2020pt
dc.relationUIDB/00308/2020pt
dc.rightsopenAccesspt
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/pt
dc.subjectTen meter Walk testpt
dc.subjectSensorspt
dc.subjectWearable devicespt
dc.subjectTelemedicinept
dc.subjectMobile devicespt
dc.subjectSystematic reviewpt
dc.titleMobile and wearable technologies for the analysis of Ten Meter Walk Test: A concise systematic reviewpt
dc.typearticle-
degois.publication.firstPagee16599pt
degois.publication.issue6pt
degois.publication.titleHeliyonpt
dc.peerreviewedyespt
dc.identifier.doi10.1016/j.heliyon.2023.e16599pt
degois.publication.volume9pt
dc.date.embargo2023-06-01*
uc.date.periodoEmbargo0pt
item.openairetypearticle-
item.fulltextCom Texto completo-
item.languageiso639-1en-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.project.grantnoInstituto de Telecomunicações-
crisitem.project.grantnoInstitute for Systems Engineering and Computers at Coimbra - INESC Coimbra-
crisitem.author.researchunitINESC Coimbra – Institute for Systems Engineering and Computers at Coimbra-
crisitem.author.orcid0000-0002-4383-0472-
Appears in Collections:FCTUC Eng.Electrotécnica - Artigos em Revistas Internacionais
I&D INESCC - Artigos em Revistas Internacionais
Files in This Item:
Show simple item record

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons