Título: Nanocellulose- based biosensor for colorimetric detection of glucose
Autor: Neubauerova, Katrin
Carneiro, Mariana C.C.G. 
Rodrigues, Lígia R.
Moreira, Felismina T. C. 
Sales, M. Goreti F. 
Palavras-chave: Nanocellulose; TEMPO-based oxidation; Glucose oxidase; Colorimetric; Test-strip Biosensor
Data: 2020
Editora: Elsevier
Projeto: P2020-PTDC/AAG-TEC/5400/2014 
POCI-01-0145-FEDER- 016637, FEDER, COMPETE, POCI 
POCTEP/INTERREG - project 2QBioneuro, Impulso de una red de I +i en química biológica para diagnóstico y tratamiento de enfermedades neurológicas 
SFRH/BD/131959/2017 
UIDB/ 04469/2020 unit and BioTecNorte operation (NORTE-01-0145-FEDER- 000004) 
Título da revista, periódico, livro ou evento: Sensing and Bio-Sensing Research
Volume: 29
Resumo: This work reports for the first time a colorimetric based biosensor using nanocellulose (NC) based supports dropdeposited onto a cellulose paper substrate for glucose detection in point-of-care. For this purpose, microcrystalline cellulose (MCC) samples were oxidized with 2,2,6,6-tetramethylpiperidine-N-oxyl radical (TEMPO), sodium hypochlorite, and potassium bromide, to produce carboxylated NC. For the characterization, we used several methods: TEM, FTIR and conductometric titration. In all samples, the primary alcohol groups were selectively oxidized into carboxyl groups, provided the sodium hypochlorite is added dropwise and the reaction is performed at constant pH 10. Carboxyl- NC was further casted on a cellulose substrate and used as support for glucose oxidase (GOx), horseradish peroxidase (HRP) and 2,2′-Azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS) reactions, aiming to yield a coloured detection system for glucose. The sensing system was generated by integrating GOx on the carboxyl- NC /cellulose substrate. Upon reaction with glucose, the enzyme produced hydrogen peroxide, which was converted into a blue-coloured product by reaction with HRP and the chromogenic reagent ABTS. The test-strip was calibrated by incubating it in different concentrations of glucose. The colours obtained were further analysed by a suitable image analysis software. Linear response for glucose ranged from 1.5 to 13.0 mM. Overall, this new test-strip used renewable material for glucose determination, which is an advantage when compared to other systems that require more complex technological approaches. Moreover, it was found that carboxyl- NC improved the colour homogeneity of the test-strip and the intrinsic linear response of concentration range.
URI: https://hdl.handle.net/10316/106720
ISSN: 22141804
DOI: 10.1016/j.sbsr.2020.100368
Direitos: openAccess
Aparece nas coleções:FCTUC Eng.Química - Artigos em Revistas Internacionais

Ficheiros deste registo:
Mostrar registo em formato completo

Citações SCOPUSTM   

26
Visto em 6/mai/2024

Citações WEB OF SCIENCETM

17
Visto em 2/mai/2024

Visualizações de página

53
Visto em 7/mai/2024

Downloads

78
Visto em 7/mai/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons