Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/106719
Title: Paper-based (bio)sensor for label-free detection of 3-nitrotyrosine in human urine samples using molecular imprinted polymer
Authors: Martins, Gabriela V. 
Marques, Ana C.
Fortunato, Elvira
Sales, M. Goreti F. 
Keywords: 3-nitrotyrosine; Molecular imprinted polymer; Electrochemical (bio)sensor; Urine biomarker; Carbon-printed electrode
Issue Date: 2020
Publisher: Elsevier
Project: PTDC/AAG-TEC/5400/2014 & POCI-01-0145- FEDER-016637 
NORTE-01-0145-FEDER-024358 
UID/CTM/50025/ 2019 
SFRH/BD/94159/2013 
SFRH/BD/115173/2016 
MindGAP/FET-Open/GA829040 
Serial title, monograph or event: Sensing and Bio-Sensing Research
Volume: 28
Abstract: Over the last years, paper technology has been widely spread as a more affordable, sustainable and reliable support material to be incorporated in the design of point-of-care (POC) diagnostic devices. However, the single work employing a paper-based device for 3-nitrotyrosine (3-NT), a relevant biomarker for oxidative stress (OS) that is a major origin for many diseases, is incapable of reading successfully complex samples because every species that oxidizes before ~0.75 V will also contribute to the final response. Thus, the introduction of a selective element was made into this set-up by including a molecularly-imprinted polymer (MIP) tailored in-situ. Herein, a novel MIP for 3-NT was assembled directly on a paper platform, made conductive with carbon ink and suitable for an electrochemical transduction. The biomimetic material was produced by electropolymerization of phenol after optimizing several experimental parameters, such a scan-rate, number of cycles, range of potential applied, monomer and template concentrations. Under optimal conditions, the label-free sensor was able to respond to 3-NT from 500 nM to 1 mM, yielding a limit of detection of 22.3 nM. Finally, the applicability of the (bio)sensor was tested by performing calibration assays in human urine samples and a good performance was obtained in terms of sensitivity, selectivity and reproducibility. Overall, the attributes of the herein described sensing approach can be compared to a very limited number of other electrochemical devices, that are still using a conventional three electrode system, making this papersustained device the first electrochemical (bio)sensor with potential to become a portable and low-cost diagnostic tool for 3-NT. In general, the incorporation of molecular imprinting technology coupled to electrochemical transduction enabled the fabrication of suitable smart sensors for wide screening approaches.
URI: https://hdl.handle.net/10316/106719
ISSN: 22141804
DOI: 10.1016/j.sbsr.2020.100333
Rights: openAccess
Appears in Collections:FCTUC Eng.Química - Artigos em Revistas Internacionais

Show full item record

SCOPUSTM   
Citations

37
checked on Apr 22, 2024

WEB OF SCIENCETM
Citations

28
checked on Apr 2, 2024

Page view(s)

37
checked on Apr 23, 2024

Download(s)

53
checked on Apr 23, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons