Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10316/106449
Título: | Electrochemical Evaluation of a Multi-Site Clinical Depth Recording Electrode for Monitoring Cerebral Tissue Oxygen | Autor: | Ledo, Ana Fernandes, Eliana Quintero, Jorge E. Gerhardt, Greg A. Barbosa, Rui M. |
Palavras-chave: | brain tissue oxygen; in vivo monitoring; multi-site clinical depth electrode | Data: | 28-Jun-2020 | Editora: | MDPI | Projeto: | POCI-01-0145-FEDER-028261 UIDB/04539/2020 |
Título da revista, periódico, livro ou evento: | Micromachines | Volume: | 11 | Número: | 7 | Resumo: | The intracranial measurement of local cerebral tissue oxygen levels-PbtO2-has become a useful tool for the critical care unit to investigate severe trauma and ischemia injury in patients. Our preliminary work in animal models supports the hypothesis that multi-site depth electrode recording of PbtO2 may give surgeons and critical care providers needed information about brain viability and the capacity for better recovery. Here, we present a surface morphology characterization and an electrochemical evaluation of the analytical properties toward oxygen detection of an FDA-approved, commercially available, clinical grade depth recording electrode comprising 12 Pt recording contacts. We found that the surface of the recording sites is composed of a thin film of smooth Pt and that the electrochemical behavior evaluated by cyclic voltammetry in acidic and neutral electrolyte is typical of polycrystalline Pt surface. The smoothness of the Pt surface was further corroborated by determination of the electrochemical active surface, confirming a roughness factor of 0.9. At an optimal working potential of -0.6 V vs. Ag/AgCl, the sensor displayed suitable values of sensitivity and limit of detection for in vivo PbtO2 measurements. Based on the reported catalytical properties of Pt toward the electroreduction reaction of O2, we propose that these probes could be repurposed for multisite monitoring of PbtO2 in vivo in the human brain. | URI: | https://hdl.handle.net/10316/106449 | ISSN: | 2072-666X | DOI: | 10.3390/mi11070632 | Direitos: | openAccess |
Aparece nas coleções: | FFUC- Artigos em Revistas Internacionais I&D CNC - Artigos em Revistas Internacionais I&D CIBB - Artigos em Revistas Internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Electrochemical-evaluation-of-a-multisite-clinical-depth-recording-electrode-for-monitoring-cerebral-tissue-oxygenMicromachines.pdf | 3.92 MB | Adobe PDF | Ver/Abrir |
Citações SCOPUSTM
8
Visto em 4/nov/2024
Citações WEB OF SCIENCETM
4
Visto em 2/nov/2024
Visualizações de página
103
Visto em 5/nov/2024
Downloads
41
Visto em 5/nov/2024
Google ScholarTM
Verificar
Altmetric
Altmetric
Este registo está protegido por Licença Creative Commons