Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/104485
DC FieldValueLanguage
dc.contributor.advisorLourenço, Ana Salomé dos Santos Pires-
dc.contributor.advisorPaula, Anabela Baptista Pereira-
dc.contributor.authorNeves, Pedro Henrique Fernandes-
dc.date.accessioned2023-01-12T23:01:47Z-
dc.date.available2023-01-12T23:01:47Z-
dc.date.issued2022-07-19-
dc.date.submitted2023-01-12-
dc.identifier.urihttps://hdl.handle.net/10316/104485-
dc.descriptionTrabalho Final do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de Medicina-
dc.description.abstractAs resinas compostas bioativas hibrídas, combinam os benefícios dos cimentos ionómeros de vidro com as resinas compostas. A sua auto-adesividade é alcançada através de ácidos funcionais poliacrílicos e grupos carboxílicos, hibridizando a “smear layer” e estabelecendo interações iónicas entre o cálcio da dentina. Estes materiais são definidos como tendo boa estética, tolerância à humidade, durabilidade, simplicidade na técnica e na manipulação, mantendo uma baixa taxa de microfiltração, enquanto libertam cálcio, fosfato e flúor. O objetivo do presente estudo foi avaliar a microinfiltração em restaurações que utilizavam a resina bioativa Surefill One™. A hipótese nula é que este tipo de resina não obtenha menor taxa de microinfiltração quando comparada com outros materiais. Foi realizado um estudo in vitro utilizando trinta e seis pré-molares e molares humanos íntegros. Foram assim realizadas preparações idênticas em todos eles (Classe V com 4 mm mesio-distal, 3 mm ocluso-gengival e 3 mm de profundidade) e divididos pelos diferentes grupos experimentais: 1 controlo positivo, 1 controlo negativo e 2 testes com resina composta bioativa e resina composta convencional (Surefill One™ e Spectra™ ST HV, respetivamente). Através de técnicas quantitativas com recurso a Medicina Nuclear foi possível avaliar a microinfiltração através da utilização de um isótopo radioativo, o tecnécio. A radioatividade emitida pelos espécimes foi detetada por uma câmara gama.Os resultados do estudo experimental apontam para diferenças estatisticamente significativas entre os grupos teste, com aumento da microinfiltração no grupo de resina composta bioativa.Com base no presente estudo de microinfiltração, foi possível concluir que a resina composta bioativa (Surefill One™) não reduz a taxa microinfiltração quando comparada a uma resina composta nanohibrida convencional (Spectra™ ST HV). O desempenho do Surefill One™ deve ser avaliado com estudos “in vitro” de maior amostra e estudos clínicos de longo prazo.por
dc.description.abstractHybrid bioactive composite resins combine the benefits of glass ionomer cements with composite resins. Its self-adhesiveness is achieved through functional polyacrylic acids and carboxylic groups, hybridizing the smear layer and establishing ionic interactions between calcium and dentin. These materials are defined as having good aesthetics, moisture tolerance, durability, simplicity in technique and handling, maintaining a low microfiltration rate, while releasing calcium, phosphate and fluorine.The aim of the present study was to evaluate microleakage in restorations using Surefill One™ bioactive resin. The null hypothesis is that this type of resin does not obtain a lower microleakage rate when compared to other materials.An in vitro study was carried out using thirty-six intact premolars and molars. Identical preparations were thus performed in all of them (Class V with 4 mm mesio-distal, 3 mm occluso-gingival and 3 mm in depth) and divided into different experimental groups: 1 positive control, 1 negative control and 2 tests with bioactive composite resin and conventional composite resin (Surefill One™ and Spectra™ ST HV, respectively). Through quantitative techniques using Nuclear Medicine, it was possible to evaluate microleakage through the use of a radioactive isotope, technetium. Radioactivity emitted by the specimens was detected by a gamma camera.The results of the experimental study point to statistically significant differences between the test groups, with increased microleakage in the bioactive composite resin group.Based on the present microleakage study, it was possible to wrap up that the bioactive composite resin (Surefill One™) does not reduce the microleakage rate when compared to a conventional nanohybrid composite resin (Spectra™ ST HV). Surefill One™ performance should be evaluated with larger sample “in vitro” studies and long-term clinical studies.eng
dc.language.isopor-
dc.rightsembargoedAccess-
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.subjectdentisteria operatóriapor
dc.subjectresina bioativapor
dc.subjectresinas compostaspor
dc.subjectmicroinfiltraçãopor
dc.subjectradioisótopospor
dc.subjectoperative dentistryeng
dc.subjectbioactive resineng
dc.subjectcomposite resinseng
dc.subjectmicroleakageeng
dc.subjectradioisotopeseng
dc.titleAvaliação da microinfiltração de um novo material bioativo para restauração de dentes posteriorespor
dc.title.alternativeEvaluation of microleakage of a new bioactive material for restoration of posterior teetheng
dc.typemasterThesis-
degois.publication.locationÁrea de Medicina Dentária, Faculdade de Medicina da Universidade de Coimbra / ICBR-
degois.publication.titleAvaliação da microinfiltração de um novo material bioativo para restauração de dentes posteriorespor
dc.date.embargoEndDate2024-07-18-
dc.peerreviewedyes-
dc.date.embargo2024-07-18*
dc.identifier.tid203158644-
thesis.degree.disciplineMedicina Dentária-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado Integrado em Medicina Dentária-
uc.degree.grantorUnitFaculdade de Medicina-
uc.degree.grantorID0500-
uc.contributor.authorNeves, Pedro Henrique Fernandes::0000-0002-6264-3285-
uc.degree.classification20-
uc.date.periodoEmbargo730-
uc.degree.presidentejuriBotelho, Maria Filomena Rabaça Roque-
uc.degree.elementojuriAbrantes, Ana Margarida Coelho-
uc.degree.elementojuriPaula, Anabela Baptista Pereira-
uc.contributor.advisorLourenço, Ana Salomé dos Santos Pires::0000-0001-7994-4650-
uc.contributor.advisorPaula, Anabela Baptista Pereira::0000-0001-6154-4173-
item.openairetypemasterThesis-
item.fulltextCom Texto completo-
item.languageiso639-1pt-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
File Description SizeFormat
_Tese_ PN_ .pdf639.81 kBAdobe PDFView/Open
Show simple item record

Page view(s)

88
checked on Jul 16, 2024

Download(s)

6
checked on Jul 16, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons