dc.descriptionTrabalho de Projeto do Mestrado Integrado em Engenharia Biomédica apresentado à Faculdade de Ciências e Tecnologia-
dc.description.abstractNos últimos anos, a microscopia multifotónica emergiu como uma prolixa área de investigação e como uma ferramenta pré-clínica para observação detalhada do comportamento celular e metabólico. A microscopia multifotónica permite imagens profundas, devido à sua capacidade de penetrar nos tecidos ao mesmo tempo que induz reduzida fototoxicidade. Isto torna a microscopia multifotónica adequada para observações a longo prazo em tecidos vivos.O microscópio multifotónico pode ser aplicado em células sem rótulo com componentes fluorescentes naturais ou aplicado em células com fluoróforos administrados. Cada fluoróforo é excitado pela luz com uma gama específica de comprimentos de onda.Recentemente, as vantagens dos lasers de ultra-banda de poucos ciclos promoveram o desenvolvimento da tecnologia SyncRGB-FLIM. Esta tecnologia incorpora um procedimento de imagem integrado e é muito eficiente na distinção de diferentes áreas pela sua distribuição de fluorescência durante a sua vida útil. Esta tese descreve o desenvolvimento de software dedicado de controlo de dispositivos e análise de dados que permite o uso do microscópio SyncRGB-FLIM. O controlo de dispositivos e análise de dados permite a criação de imagens em tempo real de células rotuladas com um máximo de três fluoróforos.O software foi testado em laboratório, onde os primeiros dados de imagem foram recolhidos e analisados em amostras celulares manchadas de várias cores em tempo real. Demonstra-se que dois ou mais cromóforos podem ser distinguidos apenas pela sua fluorescência, utilizando apenas um único detetor.por
dc.description.abstractOver the past years, multiphoton microscopy has emerged as a powerful research stream and pre-clinical tool for observing detailed cellular and metabolic behaviour. Multiphoton microscopy allows deep imaging, due to its ability to penetrate tissues while inducing reduced phototoxicity. This makes multiphoton microscopy suitable for long-term observations in living tissues.Multiphoton microscopy can be applied to label-free cells with natural fluorescent components or applied in cells with administrated fluorophores. Each fluorophore is excited by a specific wavelength range.Recently, advantages in ultrabroadband few-cycle lasers have promoted the development of SyncRGB-FLIM technology. This technology has an integrated imaging procedure and takes advantage on distinguishing different areas by their fluorescence lifetime distribution. This is possible due to the broad spectral profile of the few-cycle lasers, exciting fluorophores with different wavelength excitation ranges.This thesis describes the development of dedicated device control and data analysis software that enables the use of SyncRGB-FLIM microscopy. The device control and data analysis allow the creation of real-time imaging of cells labelled with up to three fluorophores.The software was tested in the laboratory, where first image data was collected and analyzed on multi colour-stained cellular samples in real-time. It is shown that two or more chromophores can be distinguished merely by their fluorescence using just a single detector.eng
dc.language.isoeng-
dc.rightsembargoedAccess-
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.subjectMicroscopia Multifotónica Fluorescentepor
dc.subjectAnalise de Dadospor
dc.subjectControlo de Dispositivospor
dc.subjectSyncRGB-FLIMpor
dc.subjectFluorescence Multiphoton Microscopyeng
dc.subjectData Analysiseng
dc.subjectDevice Controleng
dc.subjectSyncRGB-FLIMeng
dc.titleDevelopment of Device Control and Real-Time Data Analysis Methods for a Nonlinear Multiphoton Fluorescence Lifetime Imaging Microscopy (MP-FLIM) Systemeng
dc.title.alternativeDesenvolvimento de Métodos de Controlo de Dispositivos e Análise de Dados em Tempo Real para um Sistema de Microscopia de Imagem Multifotão Não Linear de Fluorescência (MP-FLIM)por
dc.typemasterThesis-
degois.publication.locationInternational Iberian Nanotechnology Laboratory-
degois.publication.titleDevelopment of Device Control and Real-Time Data Analysis Methods for a Nonlinear Multiphoton Fluorescence Lifetime Imaging Microscopy (MP-FLIM) Systemeng
dc.date.embargoEndDate2024-02-28-
dc.peerreviewedyes-
dc.date.embargo2024-02-28*
dc.identifier.tid203002016-
thesis.degree.disciplineEngenharia Biomédica-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado Integrado em Engenharia Biomédica-
uc.degree.grantorUnitFaculdade de Ciências e Tecnologia - Departamento de Física-
uc.degree.grantorID0500-
uc.contributor.authorSebastião, Hugo Miguel Virtuoso Simões::0000-0001-6745-5702-
uc.degree.classification18-
uc.date.periodoEmbargo730-
uc.degree.presidentejuriCortes, Luísa Maria Oliveira Pinheiro Leitão-
uc.degree.elementojuriNieder, Jana Berit-
uc.degree.elementojuriCardoso, João Manuel Rendeiro-
uc.contributor.advisorMorgado, António Miguel Lino Santos::0000-0001-9455-1206-
uc.contributor.advisorNieder, Jana Berit-
item.openairetypemasterThesis-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
File Description SizeFormat
tesehugo2022_v1.1.pdf3.45 MBAdobe PDFView/Open
Show simple item record

Page view(s)

109
checked on Mar 26, 2024

Download(s)

7
checked on Mar 26, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons