Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/94325
Title: | Conforto térmico exterior em zonas urbanas: contributos de levantamentos expeditos na pré-avaliação de ações | Other Titles: | Outdoor thermal comfort in urban areas: expeditious surveys contributions in the pre-assessment of actions | Authors: | Malaguerra, Rita Isabel Pedro | Orientador: | Lima, Maria Isabel Mendes Leal Pereira Pedroso de | Keywords: | Resiliência; Índice PET; Conforto térmico; Heat Stress; Soluções baseadas na natureza; Resilience; PET index; Thermal comfort; Heat Stress; Nature-based solutions | Issue Date: | 17-Feb-2021 | metadata.degois.publication.title: | Conforto térmico exterior em zonas urbanas: contributos de levantamentos expeditos na pré-avaliação de ações | metadata.degois.publication.location: | DEC-FCTUC | Abstract: | As alterações climáticas e os seus consequentes efeitos na sociedade, em particular nas zonas urbanas, são uma realidade cada vez mais presente e inevitável. Com base nesta premissa, a presente dissertação visa contribuir para a avaliação do conforto térmico e aferir o risco de heat stress a partir da identificação de um conjunto de parâmetros (individuais, ambientais e gerais), de metodologias e de soluções a aplicar numa área específica: o Campus Universitário Polo II, da Universidade de Coimbra. Começou-se por realizar uma revisão bibliográfica para situar e compreender os efeitos das alterações climáticas. Em seguida, procedeu-se à recolha de dados sobre parâmetros ambientais em 6 Zonas de duas ruas na área de estudo, em dois períodos do dia (13h-14h e das 19h-20h). Posteriormente, procedeu-se a uma análise de sensibilidade por forma a aferir quais dos parâmetros ambientais recolhidos mais influenciam o cálculo do índice PET (Physiological Equivalent Temperature). Seguidamente, procedeu-se à seleção de dois dias (um para cada período de medição), para cada uma das 6 Zonas. Depois de selecionados, os dados correspondentes a cada dia foram inseridos no software RayMan Pro, para determinar valores para o índice PET, que permitem avaliar o nível de perceção térmica e o nível de stress físico. Em seguida, os resultados obtidos foram partilhados através da aplicação Climate Scan. Por fim, propuseram-se soluções baseadas na natureza, com recurso ao software SketchUp Pro, de modo a contribuir para a adaptação relativa do ambiente construído, para mitigar o risco de heat stress e melhorar o conforto térmico. Os principais resultados desta dissertação determinaram os parâmetros ambientais que mais influenciaram o cálculo do índice PET neste estudo: a temperatura do ar, a velocidade do vento, a temperatura de superfície e a radiação solar. E concluiu-se que existe risco de heat stress nas 6 Zonas em estudo. Climate change and its consequent effects on society, particularly in urban areas, are an increasingly present and inevitable reality. Based on this premise, the aim of this dissertation is to contribute to the assessment of thermal comfort and to measure the risk of heat stress, based on the identification of a set of parameters (individual, environmental and general), methodologies and solutions to be applied in a specific area: The University Campus Polo II at University of Coimbra.A literature review was conducted to locate and understand the effects of climate change. Then, data on environmental parameters were collected in 6 Zones of two streets in the study area, in two periods of the day (1:00 pm to 2:00 pm and 7:00 pm to 8:00 pm). Subsequently, a sensitivity analysis was performed to assess which of the collected environmental parameters most influence the calculation of the PET (Physiological Equivalent Temperature) index. In order to compute this index, two days (one for each measurement period) were selected for each of the 6 Zones. Once selected, the data corresponding to each day were entered into the RayMan Pro software, to determine values for the PET index, which allow to assess the level of thermal perception and the level of physical stress. Then, the results obtained were shared through the Climate Scan application. Finally, nature-based solutions were proposed, using SketchUp Pro software, to contribute to the relative adaptation of the built environment, to mitigate the risk of heat stress and improve thermal comfort.The main results of this dissertation determined the environmental parameters that most influenced the calculation of the PET index in this study: air temperature, wind speed, surface temperature and solar radiation. And it concludes that there is a risk of heat stress in the 6 Zones under study. |
Description: | Dissertação de Mestrado Integrado em Engenharia Civil apresentada à Faculdade de Ciências e Tecnologia | URI: | https://hdl.handle.net/10316/94325 | Rights: | openAccess |
Appears in Collections: | UC - Dissertações de Mestrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
CONFORTO TÉRMICO EXTERIOR EM ZONAS URBANAS CONTRIBUTOS DE LEVANTAMENTOS EXPEDITOS NA PRÉ-AVALIAÇÃO DE AÇÕES.pdf | 3.35 MB | Adobe PDF | View/Open |
Page view(s)
163
checked on Nov 6, 2024
Download(s)
217
checked on Nov 6, 2024
Google ScholarTM
Check
This item is licensed under a Creative Commons License