Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/89581
DC FieldValueLanguage
dc.contributor.advisorRamos, João Carlos Tomás-
dc.contributor.advisorMartins, Orlando Paulo Moreira-
dc.contributor.authorVarela, Carolina Figueiredo-
dc.date.accessioned2020-06-19T22:00:23Z-
dc.date.available2020-06-19T22:00:23Z-
dc.date.issued2019-07-22-
dc.date.submitted2020-06-19-
dc.identifier.urihttps://hdl.handle.net/10316/89581-
dc.descriptionTrabalho Final do Mestrado Integrado em Medicina Dentária apresentado à Faculdade de Medicina-
dc.description.abstractIntrodução: A implantoplastia é uma opção terapêutica usada no tratamento da peri-implantite. Este procedimento consiste na remoção da superfície externa, contaminada, do implante, conduzindo a uma superfície menos propícia à adesão do biofilme.Objetivo: Avaliar o impacto da implantoplastia na resistência do implante à fratura. Quantificar a perda de estrutura após implantoplastia e avaliar a sua influência na resistência do implante.Metodologia: Vinte e seis implantes foram divididos em dois grupos: (Grupo Teste; GT - com implantoplastia; n=13) e (Grupo Controlo; GC - sem implantoplastia; n=13). A cada implante do grupo teste foi feito o scan, antes e após a implantoplastia, determinando-se assim a diferença de volume (volume difference - VD). Com recurso a um paquímetro digital foi determinado, para o (GT), a diferença de diâmetro do implante pré e pós implantoplastia (DD). Ambos os grupos foram submetidos a testes de compressão, avaliando as alterações da resistência à fratura. Cada variável foi analisada de modo a investigar a existência de diferenças estatisticamente significativas em ambos os grupos e a correlacionar a perda de volume e de diâmetro com a resistência à fratura.Resultados: No GT foi possível determinar um VD de 11,480±2,436. No mesmo grupo o DD foi de 0.305±0.084mm. No GC a média da força máxima aplicada foi Fmáx (798,724N ± 213,282N) e no GT de (815,466N ± 105,712N). Não se verificou correlação estatisticamente significativa entre o volume e a Fmáx nos implantes do GT, nem entre o diâmetro e a Fmáx.Discussão e Conclusão: Tendo em conta as limitações do presente estudo, a implantoplastia não mostrou uma influência significativa na resistência dos implantes aos testes de compressão. Contudo, os modos de falha do GT mostraram um maior grau de severidade. Os resultados sugerem que o VD e o DD não influenciaram a resistência do implante à fratura. Porém, não foi possível estabelecer uma correlação estatisticamente significante entre cada uma das medidas e a Fmáx.por
dc.description.abstractIntroduction: Implantoplasty (IP) is a possible treatment for peri-implantitis which consists on the removal of contaminated external surface of the implant, leading to a less suitable surface for biofilm formation. However, the physical alterations created have biomechanical consequences.Objetive: Quantify the lost structure after implantoplasty and evaluate its impact on the resistance to fracture of the implant. Methodology: 26 implants were randomly divided into two groups: (Test Group – implantoplasty; n=13) and (Control Group, CG- without implantoplasty n=13). Each implant of the TG was scanned before and after implantoplasty, to determine the difference in volume VD. Using a digital pachymeter it was determined the DD pre and post implantoplasty for the TG. Both Control and Test group were submitted to compression test, to evaluate its resistance to fracture. With adequate statistical tests, each variable was analyzed to prove if there was any statistically significant difference between both groups and correlate the reduction in volume with resistance to fracture.Results: In the TG it was analyzed a VD of 11,48 ±2,436mm³. In the same group the DD was 0.305±0.084mm. In the CG the mean Fmax (798,724 ± 213,282N) and Test group (815,466± 105,712N). It wasn’t verified a statistically significant correlation between VD and Fmax in the GT, neither with DD and Fmax. Discussion and Conclusion: Within the limitations of this study, implantoplasty didn’t show a significant difference in maximum force supported by the implant before fracture. However, the mode of failure in TG were more severe. DD and VD didn’t influence the maximum forces achieved by the implants, but it was not possible to establish statistically significant correlation.eng
dc.language.isoeng-
dc.rightsclosedAccess-
dc.rights.urihttp://creativecommons.org/licenses/by-sa/4.0/-
dc.subjectperi-implantitepor
dc.subjectimplantoplastiapor
dc.subjectimplantes dentáriospor
dc.subjectmodo de fraturapor
dc.subjecttratamentopor
dc.subjectPeri-implantitiseng
dc.subjectimplantoplastyeng
dc.subjectdental implantseng
dc.subjectfracture modeeng
dc.subjecttreatmenteng
dc.titleEvaluation of implant characteristics after implantoplasty - in vitro studyeng
dc.title.alternativeAnálise das características do implante após implantoplastia - estudo in vitropor
dc.typemasterThesis-
degois.publication.locationDepartamento de Medicina Dentária da Faculdade de Medicina da Universidade de Coimbra-
degois.publication.titleEvaluation of implant characteristics after implantoplasty - in vitro studyeng
dc.peerreviewedyes-
dc.identifier.tid202480208-
thesis.degree.disciplineMedicina Dentária-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado Integrado em Medicina Dentária-
uc.degree.grantorUnitFaculdade de Medicina-
uc.degree.grantorID0500-
uc.contributor.authorVarela, Carolina Figueiredo::0000-0002-8973-3176-
uc.degree.classification19-
uc.degree.presidentejuriMatos, Sérgio Miguel Andrade-
uc.degree.elementojuriMoreira, Filipe André Freire da Fonseca-
uc.degree.elementojuriMartins, Orlando Paulo Moreira-
uc.contributor.advisorRamos, João Carlos Tomás-
uc.contributor.advisorMartins, Orlando Paulo Moreira-
item.openairetypemasterThesis-
item.fulltextCom Texto completo-
item.languageiso639-1en-
item.grantfulltextreserved-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.advisor.orcid0000-0003-1965-1092-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
File Description SizeFormat Login
Tese (pdf) Carolina Varela.pdf1.11 MBAdobe PDF    Request a copy
Show simple item record

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons