Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/86613
DC FieldValueLanguage
dc.contributor.advisorVeludo, Etelvina-
dc.contributor.advisorPereira, Jorge Luís Gabriel Ferreira da Silva Costa-
dc.contributor.authorTeixeira, Mafalda Daniela Leite-
dc.date.accessioned2019-04-17T22:31:45Z-
dc.date.available2019-04-17T22:31:45Z-
dc.date.issued2018-09-27-
dc.date.submitted2019-04-17-
dc.identifier.urihttps://hdl.handle.net/10316/86613-
dc.descriptionDissertação de Mestrado em Química apresentada à Faculdade de Ciências e Tecnologia-
dc.description.abstractNo presente trabalho, utilizou-se a técnica HPLC para o desenvolvimento e otimização de métodos de quantificação de biocidas em tintas e matérias-primas sendo que todos eles foram validados. Do ponto de vista da empresa, é importante controlar quantitativamente os biocidas presentes nas suas tintas, de modo a cumprir todos os regulamentos e mantendo a qualidade dos seus produtos, sem prejudicar a saúde humana, animal e o ambiente. O desenvolvimento do método 1 apresenta diversas vantagens para a CIN. O fato de permitir a quantificação de três biocidas em simultâneo num curto espaço de tempo, aumenta bastante a eficácia com que se consegue identificar estes biocidas em amostras desconhecidas, e ainda quantificá-los nestas e noutro tipo de amostras. Com o desenvolvimento dos métodos 1, 2, 3 e 4, foram obtidas reduções do tempo de análise de cerca de 80, 70, 60 e 50 %, respetivamente. Tal reflete-se ainda numa diminuição do custo por análise, tornando estes novos métodos bastante vantajosos para a empresa, uma vez que serão capazes de efetuar análises precisas e rápidas.É também de grande interesse para a CIN a realização de análises microbiológicas às tintas e suas matérias-primas, para além da adição dos biocidas. No decorrer deste projeto, foi implementado um método inovador de avaliação microbiológica rápida que permitiu a obtenção de resultados em apenas oito minutos, contrariamente às quarenta e oito horas através do método anterior. Além disso, este método fornece resultados quantitativos enquanto o anterior é apenas um método semiquantitativo. Estes dois aspetos demonstram ser de grande interesse para a empresa. Quando ensaiados em paralelo, constatou-se que ambos os métodos permitem indicar da mesma forma as amostras como apresentando ou não contaminação, pelo que se considerou o novo método validado para estas gamas.Ao longo do presente trabalho, foi ainda utilizada a técnica analítica FT-NIR. O trabalho desenvolvido com esta técnica consistiu no desenvolvimento/otimização de métodos quimiométricos para a identificação de produtos/matérias-primas. Este trabalho é importante do ponto de vista da CIN, uma vez que os modelos NIR necessitam de otimizações periódicas, mas também porque a empresa pretendia ampliar a gama de produtos a controlar por esta técnica. No total foram desenvolvidas treze calibrações e otimizadas trinta e uma. Estes modelos desenvolvidos são capazes de identificar corretamente as amostras e rejeitar todas as outras, tornando-se numa vantagem para a CIN.por
dc.description.abstractThis project was made with the HPLC technique for the development and optimization of biocides quantification methods in paints and raw materials. All of these were validated. According to the company, it is important to control the quantity of biocides in their paints, in order to fulfil with all regulations without impacting on the quality of their products, without harming the human and animal health as well as the environment. The development of method 1 presents several advantages for the company. The same method allows the quantification of three biocides simultaneously in a short period of time, which significantly increases the efficiency of biocides identification in unknown samples as well as their quantification in other kind of samples. With the development of methods 1, 2, 3 and 4, analysis time reductions of about 80, 70, 60 and 50%, respectively, were obtained. Therefore, it was noted a lower analysis cost, which makes this new methods more valuable and worth for the company, as it will allow precise and faster analysis. The microbiological analysis of paints and their raw materials is also of a great interest to CIN, as well as the addition of the biocides. During the development of this project, an innovator method of rapid microbiological evaluation was implemented. This method allowed obtaining results in just eight minutes when compared to the previous method which it took forty eight hours. Furthermore, this method gives quantitative results, while the previous one it is just semiquantitative. Both of these features seems to be quite relevant to the company. As both methods showed that samples are contaminated, or not, in the same way, when performed simultaneously, the new method was considered validate for this ranges. The analytic technique FT-NIR was also used in this project. The work developed with this technique consisted of development/optimization of the chemometric methods for the products/raw materials identification. According to CIN, this tecnhique is essential as the NIR models need periodic optimizations. Also, the company intended to amplify the range of products controlled by this technique. In total, thirteen calibrations were performed and thirty one were optimized. The methods developed here are able to correctly identify samples and reject all the others, which is a advantage to CIN.eng
dc.language.isopor-
dc.rightsopenAccess-
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.subjectHPLCpor
dc.subjectATP-bioluminescênciapor
dc.subjectFT-NIRpor
dc.subjectValidação de métodos analíticospor
dc.subjectQuimiometriapor
dc.subjectHPLCeng
dc.subjectATP-bioluminescenceeng
dc.subjectFT-NIReng
dc.subjectValidation of analytical methodseng
dc.subjectChemometricseng
dc.titleControlo Químico da Qualidade de Tintaspor
dc.title.alternativeChemical Quality Control of Paintseng
dc.typemasterThesis-
degois.publication.locationCIN - Corporação Industrial do Norte, S.A.-
degois.publication.titleControlo Químico da Qualidade de Tintaspor
dc.peerreviewedyes-
dc.identifier.tid202220060-
thesis.degree.disciplineQuímica-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado em Química-
uc.degree.grantorUnitFaculdade de Ciências e Tecnologia - Departamento de Química-
uc.degree.grantorID0500-
uc.contributor.authorTeixeira, Mafalda Daniela Leite::0000-0002-1550-8742-
uc.degree.classification18-
uc.degree.presidentejuriSilvestre, Maria João Pedrosa Ferreira Moreno-
uc.degree.elementojuriPereira, Jorge Luís Gabriel Ferreira da Silva Costa-
uc.degree.elementojuriLapo, Maria Emília Dias Gonçalves Azenha-
uc.contributor.advisorVeludo, Etelvina-
uc.contributor.advisorPereira, Jorge Luís Gabriel Ferreira da Silva Costa::0000-0002-8633-3716-
item.cerifentitytypePublications-
item.languageiso639-1pt-
item.fulltextCom Texto completo-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypemasterThesis-
crisitem.advisor.deptFaculty of Sciences and Technology-
crisitem.advisor.parentdeptUniversity of Coimbra-
crisitem.advisor.researchunitCQC - Coimbra Chemistry Centre-
crisitem.advisor.parentresearchunitFaculty of Sciences and Technology-
crisitem.advisor.orcid0000-0002-8633-3716-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
File Description SizeFormat
Tese_Mafalda_Teixeira.pdf5.63 MBAdobe PDFView/Open
Show simple item record

Page view(s) 50

653
checked on May 22, 2024

Download(s) 50

699
checked on May 22, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons