Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/86602
Title: Fachadas Envidraçadas: Estado da Arte e Exigências de Ensaio
Other Titles: Glazed Facades: State of the Art and Testing Requirements
Authors: Costa, Kevin Dias 
Orientador: Simões, Nuno Albino Vieira
Keywords: Fachada cortina; Fachada de vidro suspenso; harmonized European Norm (EN); Marcação CE; estrutura de suporte; Curtain Wall; Structural Glass Facade; Norma Europeia harmonizada; CE marking; backer-structure
Issue Date: 7-Feb-2019
Serial title, monograph or event: Fachadas Envidraçadas: Estado da Arte e Exigências de Ensaio
Place of publication or event: DEC - FCTUC
Abstract: A arquitetura atual tem priveliagiado cada vez mais o uso de fachadas envidraçadas. Sobretudo em edifícios de comércio e serviços, o elemento vidro surge algumas vezes a ocupar uma elevada percentagem da fachada. Tem-se verificado que o mercado oferece diversos mecanismos de fixação do vidro e diferentes modos de ligação à estrutura do edifício.Com esta motivação, na presente dissertação realizou-se um estado da arte das principais soluções existentes no mercado e também das exigências de ensaio aplicáveis a este tipo de soluções. A primeira metade da dissertação foi dedicada à caracterização e diferenciação em duas grandes classes, as “Curtain Walls” e “Structural Glass Facades”. Se para a primeira existe uma norma harmonizada onde se definem claramente as características da solução, bem como os ensaios de caracterização, já para a segunda, sendo uma classe mais recente, verificou-se que se encontra pouca informação disponível. Uma vez que o mercado impõe exigências de marcação CE, numa segunda parte deste trabalho discute-se as alternativas para levar a cabo a certificação deste tipo de soluções, em particular das mais inovadoras. É de salientar que há um conjunto de soluções no mercado (“Structural Glass Facades”) que não dispõem de quaisquer documentos de referência para a sua caracterização. Por essa razão, outra preocupação deste trabalho foi fazer o levantamento dos ensaios correntes das “Curtain Walls” e avaliar a sua aplicabilidade.No entanto, por terem características e comportamentos tão diferentes das “Curtain Walls”, alerta-se para a necessidade de implementação de procedimentos de ensaio específicos ou recurso a análises numéricas avançadas. Deu-se, no âmbito deste trabalho, importância ao comportamento mecânico dos sistemas completos “Structural Glass Facades”, sem excluir a necessidade da avaliação de alguns dos componentes que compõem o sistema, em particular dos dispositivos de fixação do vidro. Naturalmente que estes sistemas merecem que se defina a avaliação do seu comportamento funcional, ou seja, e a título de exemplo, da sua permeabilidade ao ar e estanquidade à àgua. É urgente que se produza documentação técnica adequada a estas soluções “Structural Glass Facades” que o mercado oferece e que tem sofrido um grande crescimento nas últimas décadas.
The current architecture has increasingly privileged the use of glazed facades. Especially in commercial buildings and services, the glass element sometimes appears to occupy a high percentage of the facade. It has been verified that the market offers several mechanisms of fixation of the glass and different ways of connection to the structure of the building.With this motivation, in this dissertation was realized a state of the art of the main solutions existing in the market and also of the test requirements applicable to this type of solutions. The first half of the dissertation was dedicated to the characterization and differentiation in two great classes, Curtain Walls and Structural Glass Facades. If for the former class there is a harmonized standard where the characteristics of the solution are clearly defined, as well as the characterization tests, whereas for the latter for being a more recent class, little information is available.Since the market imposes CE marking requirements, a second part of this paper discusses the alternatives to carry out the certification of this type of solutions, in particular the most innovative ones. It should be noted that there are a number of solutions on the market ("Structural Glass Facades") that do not have any reference documents for their characterization. For this reason, another concern of this work was to survey the current Curtain Walls and evaluate their applicability.However, because these solutions have characteristics and behaviors that are so different from Curtain Walls, it is needed to implement specific testing procedures or use advanced numerical analysis. In this work, was important to understand the mechanical behavior of the complete Structural Glass Facades systems, without excluding the need to evaluate some of the components that make up the system, in particular glass fixtures. Of course, these systems deserve to be defined in terms of their performance, for example, their permeability to air and watertightness. There is an urgent need to produce adequate technical documentation for these Structural Glass Facades solutions that the market offers and which has undergone a great growth in the last decade.
Description: Dissertação de Mestrado Integrado em Engenharia Civil apresentada à Faculdade de Ciências e Tecnologia
URI: https://hdl.handle.net/10316/86602
Rights: openAccess
Appears in Collections:UC - Dissertações de Mestrado

Files in This Item:
Show full item record

Page view(s) 50

490
checked on Apr 16, 2024

Download(s) 50

523
checked on Apr 16, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons