Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/86150
DC FieldValueLanguage
dc.contributor.advisorSerra, Arménio Coimbra-
dc.contributor.advisorTavakoli, Mahmoud-
dc.contributor.authorLeal, Cristina Isabel Carvalho Diogo-
dc.date.accessioned2019-03-27T23:17:22Z-
dc.date.available2019-03-27T23:17:22Z-
dc.date.issued2018-09-21-
dc.date.submitted2019-03-27-
dc.identifier.urihttps://hdl.handle.net/10316/86150-
dc.descriptionTrabalho de Projeto do Mestrado Integrado em Engenharia Biomédica apresentado à Faculdade de Ciências e Tecnologia-
dc.description.abstractOs adesivos de biomonitorização que conseguem aderir à epiderme humana e detetar bio-potenciais, têm recebido cada vez mais atenção durante os últimos anos. Como em qualquer dispositivo móvel, o armazenamento de energia ainda é um grande problema. Portanto, o desenvolvimento de baterias de filme-fino (thin-film) e esticáveis que podem ser integradas em adesivos biomonitorização é altamente antecipado. Entre essas, as baterias de prata-zinco são opções interessantes devido à sua capacidade em mAh/cm^2 (comparável às baterias de lítio), o uso de componentes não inflamáveis e eletrólitos à base de água.Até recentemente, uma das principais desvantagens das baterias Ag-Zn era o seu ciclo de vida, uma vez que era muito reduzido pela destruição do elétrodo de zinco, reduzindo assim sua eficiência após cada recarga. Esse problema é agora tratado com aditivos como Mercúrio, Índio, Gálio e Bismuto.Nesta dissertação, apresentamos a fabricação e caracterização de uma bateria Ag-Zn, com capacidade de armazenamento de energia de 2,5 mAh / cm ^2, que é recarregável. Para isso, os coletores de corrente AgInGa são usados para diminuir a resistência interna da bateria e permitir que a bateria se estique, e os coletores de corrente CB + InGa ajudam com o ciclo de vida do zinco. O uso do EGaIn (metal líquido) para a arquitetura, além de permitir a preparação de elétrodos elásticos, provou melhorar o ciclo de vida da bateria, assim como a capacidade de armazenamento de energia - os resultados obtidos são semelhantes aos resultados do estado da arte. Os métodos de fabricação utilizados são simples e fáceis.Além disso, durante esta dissertação, um sistema potenciostato/galvanostato foi desenvolvido internamente ('in house'); este sistema permite medições de 2 e 3 elétrodos e a caracterização simultânea de até 12 baterias.por
dc.description.abstractBio-monitoring patches that can adhere to the human epidermis and collect bio-potentials have been receiving increasing attention during the last few years. As with any mobile device, the energy storage is still a major problem. Therefore, the development of thin-film and stretchable batteries that can be integrated into these bio-monitoring patches is highly anticipated. Among those, Silver-zinc batteries are interesting choices due to their capacity in mAh/cm^2 (comparable to lithium batteries), use of non-flammable components and water-based electrolytes.Until recently, one major drawback of Ag-Zn batteries was their life cycle, since it was greatly shortened by the destruction of the zinc electrode, thereby reducing their efficiency after each recharge. This problem is now addressed with additives such as Mercury, Indium, Gallium and Bismuth. In this dissertation, we present fabrication and characterization of a novel Ag-Zn battery, with an energy storage capacity of 2,5 mAh/cm^2, which is rechargeable. To do so, AgInGa current collectors are used to decrease the internal resistance of the battery and allow the battery to stretch, and CB+InGa current collectors help with the life cycle of zinc. The use of the EGaIn (liquid metal) to the architecture, not only allowed preparation of stretchable electrodes, it proved to improve the life cycle of the battery as well as its energy storage capacity. In terms of energy storage capacity, the results obtained are similar to the results of the state of the art. The fabrication methods employed are also simple and easy.In addition, during this dissertation, a \gls{pg} system was developed in-house, which allowed the simultaneous characterization of up to 12 batteries.eng
dc.description.sponsorshipOutro - This work was partially supported by the national funds of the Foundation of Science and Technology of Portugal through the CMU-Portugal project Stretchtronics (Nr. CMUP-ERI/TIC/0021/2014), and Portuguese Additive Manufacturing Initiative, PAMI (Nr. CENTRO-01-0145-FEDER-022158) and Dermotronics (02/SAICT/2017-31784).-
dc.language.isoeng-
dc.rightsembargoedAccess-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectBiomonitorizaçãopor
dc.subjectEletrónica flexívelpor
dc.subjectBateria esticávelpor
dc.subjectPrata-Zincopor
dc.subjectSIS ( Poliestireno - poliisopropeno - poliestireno)por
dc.subjectBiomonitoringeng
dc.subjectStretchable electronicseng
dc.subjectStretchable batteryeng
dc.subjectSilver-Zinceng
dc.subjectpolystyrene-polyisoprene-polystyrene.eng
dc.titleStretchable silver - zinc based battery, a novel fabrication methodeng
dc.title.alternativeBateria esticável de Prata-Zinco Um novo método de fabricaçãopor
dc.typemasterThesis-
degois.publication.locationISR, DEQ-
degois.publication.titleSTRETCHABLE SILVER - ZINC BASED BATTERY A NOVEL FABRICATION METHODeng
dc.date.embargoEndDate2024-09-19-
dc.peerreviewedyes-
dc.date.embargo2024-09-19*
dc.identifier.tid202206327-
thesis.degree.disciplineEngenharia Biomédica-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado Integrado em Engenharia Biomédica-
uc.degree.grantorUnitFaculdade de Ciências e Tecnologia - Departamento de Física-
uc.degree.grantorID0500-
uc.justificaEmbargoDue to the fact that this work is subject to intellectual properties, it can not be shared without written authorization from the involving entities.-
uc.contributor.authorLeal, Cristina Isabel Carvalho Diogo::0000-0003-1134-2260-
uc.degree.classification19-
uc.date.periodoEmbargo2190-
uc.degree.presidentejuriAlmeida, Aníbal Traça de Carvalho-
uc.degree.elementojuriCoelho, Jorge Fernando Jordão-
uc.degree.elementojuriTavakoli, Mahmoud-
uc.contributor.advisorSerra, Arménio Coimbra-
uc.contributor.advisorTavakoli, Mahmoud-
item.grantfulltextembargo_20240919-
item.fulltextCom Texto completo-
item.openairetypemasterThesis-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.advisor.researchunitCEMMPRE - Centre for Mechanical Engineering, Materials and Processes-
crisitem.advisor.researchunitISR - Institute of Systems and Robotics-
crisitem.advisor.parentresearchunitUniversity of Coimbra-
crisitem.advisor.orcid0000-0001-8664-2757-
crisitem.advisor.orcid0000-0002-2590-2196-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
File Description SizeFormat Login
Cristina_Leal_Tese.pdf25.4 MBAdobe PDFEmbargo Access    Request a copy
Show simple item record

Page view(s) 50

449
checked on Apr 23, 2024

Download(s) 50

273
checked on Apr 23, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons