Title: Medidas de Reabilitação Térmica em Habitações: Impacto na Energia e no Conforto
Other Titles: Measures of Thermal Housing Rehabilitation: Impact on Energy and Comfort
Authors: Ramos, Armando José Machado Pereira 
Orientador: Simões, Nuno Albino Vieira
Keywords: Eficiência energética; Reabilitação térmica; Conforto térmico; Energy efficiency; Thermal rehabilitation; Thermal comfort.
Issue Date: 13-Mar-2018
metadata.degois.publication.title: Medidas de Reabilitação Térmica em Habitações: Impacto na Energia e no Conforto
metadata.degois.publication.location: DEC-FCTUC
Abstract: O setor da construção é um dos grandes responsáveis pelo consumo de energia a nível global e, assim sendo, a reabilitação do edificado existente em conjunto com a nova legislação aplicável, apresenta-se como uma excelente oportunidade para se proceder a melhorias efetivas, que conduzam à redução significativa do consumo energético, ao mesmo tempo que permite reduzir as emissões de gases com efeito de estufa. No caso da União Europeia, foram impostos objetivos energéticos e climáticos para 2020. 2030 e 2050, tendo como finalidade, atingir a meta da diminuição das emissões de gases com efeito de estufa entre os 80-95%. Este valor não será alcançável sem uma intervenção profun-da na reabilitação dos edifícios, bem como nas soluções para o novo edificado.O objectivo do presente estudo centra-se na avaliação do efeito de medidas de reabilitação térmica no desempenho energético de um edifício. Para o efeito, usou-se uma habitação de referência, que serviu de base ao estudo do impacto no consumo e na rentabilidade económica, provocadas pela introdução de reforço térmico na envolvente. Nesta avaliação inicial adotou-se o método sazonal para se estimarem as necessidades energéticas de aquecimento e arrefecimento. Como a cultura de climatização em Portugal é baixa, avaliou-se numa segunda fase do trabalho o impacto de cada uma das medidas no nível de conforto do ambiente interior. Esta avaliação é realizada através da comparação da temperatura interior com a resultante no modelo de conforto térmico adaptativo descrito na norma ANSI/ASHRAE Standard 55-2013 (Thermal Environmental Conditions for Human Occupancy). A estimativa da temperatura interior do edifício de referência foi obtida através do método dinâmico, recorrendo-se ao software DesignBuilder.Este estudo é efetuado para três localizações do edifício no território nacional. A norte, no distrito de Bragança, no centro, no distrito de Coimbra e a Sul, no distrito de Faro
The construction industry is a major player in energy consumption globally, therefore the rehabilitation of the existing building together with the new applicable legislation is an excellent opportunity to make effective improvements that lead to a significant reduction in energy consumption, while reducing greenhouse gas emissions. In the European Union, energy and climate targets were set for 2020, 2030 and 2050, aiming to achieve the goal of reducing greenhouse gas emissions by 80-95%. This value will not be attainable without a thorough intervention in the rehabilitation of buildings, as well as in the solutions for the new building. The objective of the present study is to evaluate the effect of thermal rehabilitation measures on the energy performance of a building. For this purpose, a reference dwelling was used, which served as a basis for the study of the impact on consumption and economic profitabil-ity, caused by the introduction of thermal reinforcement in the surroundings. In this initial evaluation the seasonal method was adopted to estimate the energy requirements of heating and cooling. As the climate control culture in Portugal is low, the impact of each measure on the comfort level of the interior environment was evaluated in a second phase of the work. This evaluation is performed by comparing the internal temperature with the resultant in the adaptive thermal comfort model described in the ANSI / ASHRAE Standard 55-2013 (Ther-mal Environmental Conditions for Human Occupancy). The estimation of the interior temper-ature of the reference building was obtained through the dynamic method, using the Design-Builder software. This study is carried out for three building locations in the national territory. To the north, in the district of Bragança, in the center, in the district of Coimbra and to the South, in the district of Faro.
Description: Dissertação de Mestrado em Eficiência Acústica e Energética para uma Construção Sustentável apresentada à Faculdade de Ciências e Tecnologia
URI: https://hdl.handle.net/10316/84933
Rights: openAccess
Appears in Collections:UC - Dissertações de Mestrado

Files in This Item:
Show full item record

Page view(s) 50

486
checked on Oct 29, 2024

Download(s) 50

651
checked on Oct 29, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons