Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/83394
DC FieldValueLanguage
dc.contributor.advisorAlves, Francisco José Cerqueira-
dc.contributor.advisorLandeck, Jorge Afonso Cardoso-
dc.contributor.authorTondela, Joao Antonio de Sousa Machado Mota e-
dc.date.accessioned2018-12-22T19:26:04Z-
dc.date.available2018-12-22T19:26:04Z-
dc.date.issued2017-09-28-
dc.date.submitted2019-01-21-
dc.identifier.urihttps://hdl.handle.net/10316/83394-
dc.descriptionDissertação de Mestrado Integrado em Engenharia Física apresentada à Faculdade de Ciências e Tecnologia-
dc.description.abstractEsta dissertação tem como objectivo a implementação de um sistema que permita monitorizar os níveis de radioactividade de vários locais dentro do Instituto de Ciências Nucleares Aplicadas à Saúde (ICNAS). Para tal, estudou-se o actual paradigma da segurança nuclear em Portugal e quais as medidas em vigor. É necessário, também, perceber que protocolos de comunicação existem e como isso pode influenciar a implementação de tal sistema de monitorização.Nos últimos anos, a Física Nuclear tem sido amplamente estudada e aplicada às mais diversas áreas, sendo por isso mesmo importante haver informação concreta sobre a sua capacidade e também sobre os seus perigos. É com base nesta premissa que esta dissertação é desenvolvida, para que seja bem claro como fazer progressos na área da Física Nuclear em segurança. É absolutamente vital que haja um controlo de toda e qualquer radiação adjacente a qualquer projecto e trabalho nesta área para evitar males tanto para os trabalhadores como para o ambiente e a população.É aqui que surge a necessidade de no ICNAS haver um sistema de monitorização mais avançado e, ao mesmo tempo, de fácil implementação e leitura. Actualmente, este controlo é feito localmente em cada um dos módulos digitais de leitura, equipados com uma sonda, o que é, de facto, pouco prático. Nesta dissertação, são propostas soluções para este problema, fazendo uso dos conhecimentos adquiridos sobre protocolos de comunicação digital, acompanhado por um programa que lê e processa os dados obtidos, fazendo uma filtragem de modo a que a sua leitura seja facilmente interpretada.Por fim, é realizada uma validação experimental de um projecto anterior realizado no ICNAS cujo objectivo era a estimação de doses em trabalhadores do instituto que tivessem determinadas trajectórias. Foram geradas no software três trajectórias, reproduzidas na realidade, sendo que a dose é obtida através de um dosímetro e os seus valores comparados com o software.por
dc.description.abstractThe objective of this dissertation is the implementation of a system that allows the monitoring of the radioactivity levels in different locations inside the Instituto de Ciências Nucleares Aplicadas à Saúde (ICNAS). For that, it was necessary to study and understand the actual paradigm of nuclear security in Portugal and what measures are in place. It is also necessary to understand which communication protocols exist and its weight in the implementation of such monitoring system.In the last few years, Nuclear Physics has been widely studied and applied to the most various areas, which makes it so important to have factual information about its capacity and also about its dangers. It is with this in mind that this dissertation is developed, so it is clear how to proceed with this developments without any safety concerns. It's of the utmost importance to have a total control of the radiation scattered in any project and work in this area in order to avoid bigger problems, both for the workers and environment and population.From this arises the necessity of having a more advanced monitoring system in ICNAS and, at the same time, that is easy to implement and to read. Currently, this control is made locally in each digital reading module, equipped with a probe, which is, in fact, unpractical. In this dissertation it is proposed different solutions to this problem, making use of acquired knowledge in communication protocols and a program that reads and processes all the acquired data, filtering it so its reading is easily understood.Lastly, it was performed an experimental validation of a previous work done in ICNAS, whose purpose was to estimate dosages in workers inside the institute who had a certain path. It was generated three different trajectories in the software, reproduce afterwards in reality, being that the dosage was obtained through a dosimeter and its values compared to the ones from the software.eng
dc.language.isopor-
dc.rightsembargoedAccess-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/-
dc.subjectRadioactividadepor
dc.subjectSegurança Nuclearpor
dc.subjectDosimetriapor
dc.subjectMonitorização Remotapor
dc.subjectSistema de Redespor
dc.subjectRadioactivityeng
dc.subjectNuclear Securityeng
dc.subjectDosimetryeng
dc.subjectRemote monitoringeng
dc.subjectComputer Networkeng
dc.titleSistemas de Monitorização de Radioatividade Ambientalpor
dc.title.alternativeMonitoring systems for environment radioactivityeng
dc.typemasterThesis-
degois.publication.locationIBILI - ICNAS - FMUC-
degois.publication.titleSistemas de Monitorização de Radioatividade Ambientalpor
dc.date.embargoEndDate2023-09-27-
dc.peerreviewedyes-
dc.date.embargo2023-09-27*
dc.identifier.tid202123340-
thesis.degree.disciplineFísica Aplicada Tecnológica-
thesis.degree.grantorUniversidade de Coimbra-
thesis.degree.level1-
thesis.degree.nameMestrado Integrado em Engenharia Física-
uc.degree.grantorUnitFaculdade de Ciências e Tecnologia - Departamento de Física-
uc.degree.grantorID0500-
uc.contributor.authorTondela, Joao Antonio de Sousa Machado Mota e::0000-0002-7516-8735-
uc.degree.classification11-
uc.date.periodoEmbargo2190-
uc.degree.presidentejuriDomingues, José Paulo Pires-
uc.degree.elementojuriAbrunhosa, Antero José Pena Afonso de-
uc.degree.elementojuriAlves, Francisco José Cerqueira-
uc.degree.elementojuriTchepel, Vitali Iourievitch-
uc.contributor.advisorAlves, Francisco José Cerqueira-
uc.contributor.advisorLandeck, Jorge Afonso Cardoso-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.openairetypemasterThesis-
item.languageiso639-1pt-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.advisor.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.advisor.parentresearchunitUniversity of Coimbra-
crisitem.advisor.orcid0000-0001-8054-4267-
crisitem.advisor.orcid0000-0003-4666-9722-
Appears in Collections:UC - Dissertações de Mestrado
Files in This Item:
File Description SizeFormat
Tese_JoaoTondela.pdf1.66 MBAdobe PDFView/Open
Show simple item record

Page view(s) 50

480
checked on Apr 23, 2024

Download(s) 50

390
checked on Apr 23, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons