dc.identifier.citationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 516:2-3 (2004) 486-491en_US
dc.identifier.urihttps://hdl.handle.net/10316/4454-
dc.description.abstractThe response of a YAP, NaI(Tl) and BaF2 scintillators to X-rays with energies around the Y, I, and Ba K-absorption edges, respectively, was investigated. For all the scintillators, the amplitude response follows different linear trends for X-ray energies below and above the respective K-edges, presenting a discontinuity at these energies. An abrupt decrease of about 3%, 5% and 2% were observed in the detector amplitude at the K-edges, for the YAP, the NaI(Tl) and the BaF2 scintillator, respectively, corresponding to a decrease of 0.5±0.1, 1.7±0.3 and 0.8±0.2 keV in the energy calibration line. These discontinuities result in a region within 0.5±0.1, 1.6±0.3 and 0.9±0.2 keV where the X-ray energy cannot be obtained unambiguously. The scintillation yields for X-rays present abrupt decreases of about 3%, 4% and 2%, respectively, at the K-edges. The measured non-linearity effects are significantly larger than those obtained for gaseous and semiconductor detectors. The higher amplitude non-linearity observed in NaI(Tl) is attributed to the larger light yield non-linearity in the electron response of this crystal.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6TJM-49N7V56-3/1/6bc7816ad91bca6e857e9a848f8eb8a2en_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectInorganic scintillatorsen_US
dc.subjectNaI(Tl)en_US
dc.subjectEnergy non-linearityen_US
dc.titleEnergy non-linearity effects in the response of ionic crystal scintillators to X-rays with energy in the region of the K-absorptions edges: experimental resultsen_US
dc.typearticleen_US
dc.identifier.doi10.1016/j.nima.2003.08.171-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0002-7107-7203-
crisitem.author.orcid0000-0002-8841-6523-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
file8c32fa693ff5485ca2fbdc46ecb87bb0.pdf239.69 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

6
checked on Apr 22, 2024

WEB OF SCIENCETM
Citations

4
checked on Apr 2, 2024

Page view(s)

304
checked on Apr 23, 2024

Download(s)

272
checked on Apr 23, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.