Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/43833
Título: Automated lesion detectors in retinal fundus images
Autor: Figueiredo, Isabel N. 
Kumar, Sunil 
Oliveira, Carlos M. 
Ramos, João Diogo 
Engquist, Bjorn 
Palavras-chave: Algorithms; Aneurysm; Automation; Databases, Factual; Diabetic Retinopathy; Exudates and Transudates; Hemorrhage; Humans; Image Interpretation, Computer-Assisted; Image Processing, Computer-Assisted; Models, Theoretical; Multivariate Analysis; Pattern Recognition, Automated; Retina; Sensitivity and Specificity; Wavelet Analysis; Fundus Oculi
Data: 2015
Editora: Elsevier
Projeto: info:eu-repo/grantAgreement/FCT/COMPETE/132981/PT 
Título da revista, periódico, livro ou evento: Computers in Biology and Medicine
Volume: 66
Resumo: Diabetic retinopathy (DR) is a sight-threatening condition occurring in persons with diabetes, which causes progressive damage to the retina. The early detection and diagnosis of DR is vital for saving the vision of diabetic persons. The early signs of DR which appear on the surface of the retina are the dark lesions such as microaneurysms (MAs) and hemorrhages (HEMs), and bright lesions (BLs) such as exudates. In this paper, we propose a novel automated system for the detection and diagnosis of these retinal lesions by processing retinal fundus images. We devise appropriate binary classifiers for these three different types of lesions. Some novel contextual/numerical features are derived, for each lesion type, depending on its inherent properties. This is performed by analysing several wavelet bands (resulting from the isotropic undecimated wavelet transform decomposition of the retinal image green channel) and by using an appropriate combination of Hessian multiscale analysis, variational segmentation and cartoon+texture decomposition. The proposed methodology has been validated on several medical datasets, with a total of 45,770 images, using standard performance measures such as sensitivity and specificity. The individual performance, per frame, of the MA detector is 93% sensitivity and 89% specificity, of the HEM detector is 86% sensitivity and 90% specificity, and of the BL detector is 90% sensitivity and 97% specificity. Regarding the collective performance of these binary detectors, as an automated screening system for DR (meaning that a patient is considered to have DR if it is a positive patient for at least one of the detectors) it achieves an average 95-100% of sensitivity and 70% of specificity at a per patient basis. Furthermore, evaluation conducted on publicly available datasets, for comparison with other existing techniques, shows the promising potential of the proposed detectors.
URI: https://hdl.handle.net/10316/43833
DOI: 10.1016/j.compbiomed.2015.08.008
10.1016/j.compbiomed.2015.08.008
Direitos: embargoedAccess
Aparece nas coleções:I&D CMUC - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
p1440.pdf3.98 MBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações SCOPUSTM   

60
Visto em 15/abr/2024

Citações WEB OF SCIENCETM
5

49
Visto em 2/abr/2024

Visualizações de página 5

1.326
Visto em 23/abr/2024

Downloads

368
Visto em 23/abr/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.