Resumo: Operation of Gas Electron Multiplier (GEM) in ultra-pure xenon was studied for gas at 25 °C, cold but not saturated gas at -90 °C and saturated xenon vapour at -102 °C. The most stable operation was observed at -90 °C for which the maximum visible gain of 150 was obtained from a single GEM. The maximum gain of [approximate]40 was achieved for saturated xenon vapour at -102 °C and of [approximate]25 for two-phase configuration at the same temperature. Continuous operation of a GEM in two-phase mode for periods of several hours was routinely achieved.
URI: https://hdl.handle.net/10316/4360
DOI: 10.1016/j.nima.2007.05.168
Direitos: openAccess
Aparece nas coleções:FCTUC Física - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
file251d8fffabbc48b0b666ee7328e95917.pdf154.73 kBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações SCOPUSTM   

7
Visto em 9/nov/2022

Citações WEB OF SCIENCETM

6
Visto em 2/mai/2023

Visualizações de página

264
Visto em 16/abr/2024

Downloads

240
Visto em 16/abr/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.