Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/39012
DC FieldValueLanguage
dc.contributor.advisorGaspar, Adélio Manuel Rodrigues-
dc.contributor.advisorSantos, Victor Matias dos-
dc.contributor.authorReis, José António Morgado Pinto-
dc.date.accessioned2017-03-28T15:05:04Z-
dc.date.available2017-03-28T15:05:04Z-
dc.date.issued2014-09-10-
dc.identifier.urihttps://hdl.handle.net/10316/39012-
dc.descriptionDissertação de Mestrado Integrado em Engenharia Mecânica apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.pt
dc.description.abstractO consumo de energia é um tema preocupante para a manutenção do bem-estar das sociedades. O excesso de consumo contribui para o desequilíbrio ambiental, uma vez que as fontes de energia se vão esgotando, o que pode colocar em risco a sobrevivência na Terra. O presente trabalho tem como objetivo a avaliação da eficiência energética num armazém de enchimento de gás de petróleo liquefeito (GPL), realizado nas instalações de Matosinhos da REPSOL GÁS PORTUGAL, S.A. Nesse sentido, foi feito um estudo descritivo e retrospetivo do consumo de energia em todo o processo referente à movimentação de GPL nesta instalação. O trabalho teve como suporte canais de comunicação informais e formais, a observação no local de todo o processo de funcionamento e recolha de dados relativamente ao mesmo, sendo o tratamento de dados realizado de forma quantitativa. Verificou-se que o processo consome em média 120,4tep/ano de energia (99,6tep em energia eléctrica e 20,8tep em gasóleo), o que corresponde a um custo médio de 71721 euros/ano. Do total de energia elétrica consumida 38% corresponde à bombagem de GPL das esferas para o edifício, 21% ao consumo da central de ar comprimido, 15% aos transportadores das linhas, 7% à iluminação e os restantes às caldeiras de vapor, à Estação de Tratamento de Águas Residuais (ETAR), aos centros de lavagem e às bombas hidráulicas. O consumo de gasóleo é essencialmente destinado aos empilhadores. A empresa já utiliza compressor com variador de velocidade e baterias de condensadores para compensação da energia reativa. A redistribuição de funções e ajuste nos aparelhos e a atualização do tipo de iluminação reduz 10% do consumo de energia primária relativamente ao último ano, o que corresponde a uma poupança de 5400 euros. Conclui-se, portanto, a existência de elevada preocupação com a eficiência energética da instalação. Contudo, pequenos ajustes traduzem-se numa maior poupança de energia, o que se reflete num benefício em termos ambientais e de custos.pt
dc.description.abstractEnergy consumption is a concern for maintaining the well-being of societies theme. Excess consumption contributes to environmental imbalance, since energy sources are depleted, which can endanger the survival on Earth. This study aims to evaluate the energy efficiency of a gas filling center, held on the premises of the REPSOL GAS PORTUGAL, SA in Matosinhos, Portugal. A descriptive and retrospective study of energy consumption in the whole process of the movement of gas in this installation was done. The work was supported by informal and formal channels of communication, on-site observation of the whole process of operation and collection of data concerning the same, and the data processing performed quantitatively. It has been found that the process consumes an average 120,4tep / year of primary energy (99,6tep in electricity and 20,8tep in diesel engines), which corresponds to an average value of 71 721 EUR / year. Of the total electricity consumed 38% corresponds to pumping gas spheres to the building, 21% consumption of the compressed air, 15% for carriers of the lines, 7% to enlightenment and the remaining steam boilers, the station Wastewater Treatment Plant (WWTP), the centers of washing and hydraulic pumps. Diesel consumption is primarily intended for forklift. The company already uses compressor with variable speed drive and batteries condensate for reactive power compensation. The redistribution of functions and adjust the devices and update the type of lighting reduces 10% of primary energy consumption compared to last year, which represents a saving of 5400 EUR. Therefore, it is concluded that there is high concern for energy efficiency of the installation. However, minor adjustments translate into greater energy savings, which is reflected in a benefit for the environment and costs.pt
dc.language.isoporpt
dc.rightsopenAccesspt
dc.subjectEficiência energéticapt
dc.subjectAuditoria energéticapt
dc.subjectQualidadept
dc.subjectSegurançapt
dc.subjectAmbientept
dc.subjectEnergy efficiencypt
dc.subjectEnergy auditspt
dc.subjectQualitypt
dc.subjectSecuritypt
dc.subjectEnvironmentpt
dc.titleAvaliação da eficiência energética de um centro de enchimento de gáspt
dc.title.alternativeAssessment of the energy efficiency of a gas filling plantpt
dc.typemasterThesispt
degois.publication.locationCoimbrapt
dc.date.embargo2014-09-10*
dc.identifier.tid201664747pt
thesis.degree.grantor00500::Universidade de Coimbrapt
thesis.degree.nameMestrado Integrado em Engenharia Mecânicapt
uc.degree.grantorUnit0501 - Faculdade de Ciências e Tecnologiapor
uc.rechabilitacaoestrangeiranopt
uc.date.periodoEmbargo0pt
item.openairetypemasterThesis-
item.languageiso639-1pt-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
crisitem.advisor.researchunitADAI - Association for the Development of Industrial Aerodynamics-
crisitem.advisor.orcid0000-0001-6947-4579-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Mecânica - Teses de Mestrado
Files in This Item:
Show simple item record

Page view(s)

189
checked on Mar 26, 2024

Download(s) 50

816
checked on Mar 26, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.