Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/38920
DC FieldValueLanguage
dc.contributor.advisorGaspar, Adélio Manuel Rodrigues-
dc.contributor.advisorSantos, António Mexia-
dc.contributor.authorMota, Raúl Alves-
dc.date.accessioned2017-03-28T14:39:52Z-
dc.date.available2017-03-28T14:39:52Z-
dc.date.issued2015-07-29-
dc.identifier.urihttps://hdl.handle.net/10316/38920-
dc.descriptionDissertação de Mestrado Integrado em Engenharia Mecânica apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbra.pt
dc.description.abstractNo contexto atual em que a eficiência energética dos edifícios é um tópico de importância crescente, a caracterização adequada das formas de uso de energia nos hotéis é fundamental para se conseguir uma crescente utilização racional da energia. O conforto proporcionado pelas unidades hoteleiras é essencial para o seu desenvolvimento. Como tal, a hotelaria é um sector onde o uso da energia tem especial relevo nos custos totais da atividade. Neste contexto, as ferramentas de simulação computacional disponíveis, como o TRNSYS têm grandes potencialidades associadas e podem assumir um papel relevante na avaliação e otimização do desempenho energético de edifícios. O presente trabalho tem como objetivo a realização de uma análise ao comportamento do sistema de AQS do Hotel TRYP Coimbra, recorrendo ao TRNSYS. Decidiu-se focar o estudo no sistema de AQS, dado que é um dos sistemas que impõe um consumo de energia apreciável, e que, neste caso de estudo apresentava algumas dificuldades ao nível da otimização de funcionamento. Na análise do sistema de AQS estudaram-se, mais concretamente, algumas medidas de possível melhoria do sistema, tais como a alteração dos setpoints dos depósitos, dos coletores solares térmicos e das caldeiras, de forma a racionalizar os consumos de energia e potenciar ao máximo a utilização de energia renovável (coletores solares térmicos). Os resultados das simulações das diversas possibilidades de melhoria definidas, mostraram que é expectável conseguirem-se poupanças de energia de cerca de 19%.pt
dc.description.abstractIn the current context, in which the energy efficiency of buildings is a topic of growing importance, the proper characterization of the forms of energy use in hotels is critical to achieve an increasing rational use of energy. The comfort provided by the hotel units is essential for their development. As such, the hotels are a sector where energy use has special importance in the total costs of the activity. In this context, the computer simulation tools available, such as TRNSYS have great potential associated and can play a relevant role in the evaluation and optimization of the energy performance of buildings. This paper aims to conduct an analysis of the behavior of the water heating system present in Hotel Tryp Coimbra, using the TRNSYS. It was decided to focus the study on the water weating system, since it is one of the systems that requires a considerable energy consumption, and in this case study presented some difficulties with operation optimization. In the analysis of water heating system were studied, specifically, some measures that can improve the system, such as changing the setpoints of the deposits, solar thermal collectors and the boiler in order to rationalize energy consumption and enhance the most the use of renewable energy (solar thermal collectors). The simulation results of the various defined possibilities of improvement, have shown that it is expected to achieve energy savings of about 19%. Keywords , , ,pt
dc.language.isoporpt
dc.rightsopenAccesspt
dc.subjectÁgua quente sanitáriapt
dc.subjectcoletores solares térmicospt
dc.subjectTRNSYSpt
dc.subjectsimulação energética de edifíciospt
dc.subjecteficiência energéticapt
dc.subjectWater heatingpt
dc.subjectsolar thermal collectorspt
dc.subjectTRNSYSpt
dc.subjectenergetic simulation of buildingspt
dc.subjectenergy efficiencypt
dc.titleCaracterização energética e estudo de medidas de melhoria para um Hotel nZEBpt
dc.title.alternativeEnergy assesment and improvement measures for a nZEB Hotelpt
dc.typemasterThesispt
degois.publication.locationCoimbrapt
dc.date.embargo2015-07-29*
dc.identifier.tid201663988pt
thesis.degree.grantor00500::Universidade de Coimbrapt
thesis.degree.nameMestrado Integrado em Engenharia Mecânicapt
uc.degree.grantorUnit0501 - Faculdade de Ciências e Tecnologiapor
uc.rechabilitacaoestrangeiranopt
uc.date.periodoEmbargo0pt
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypemasterThesis-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1pt-
crisitem.advisor.researchunitADAI - Association for the Development of Industrial Aerodynamics-
crisitem.advisor.orcid0000-0001-6947-4579-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Mecânica - Teses de Mestrado
Files in This Item:
File Description SizeFormat
150 RaulMota.pdf2.09 MBAdobe PDFView/Open
Show simple item record

Page view(s)

193
checked on Apr 23, 2024

Download(s)

201
checked on Apr 23, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.