DC Field | Value | Language |
---|---|---|
dc.contributor.author | Afonso, P. A. F. N. A. | - |
dc.contributor.author | Ferreira, J. M. L. | - |
dc.contributor.author | Castro, J. A. A. M. | - |
dc.date.accessioned | 2008-08-29T15:27:26Z | - |
dc.date.available | 2008-08-29T15:27:26Z | - |
dc.date.issued | 1998 | en_US |
dc.identifier.citation | Chemical Engineering Research and Design. 76:4 (1998) 490-498 | en_US |
dc.identifier.uri | https://hdl.handle.net/10316/3848 | - |
dc.description.abstract | The experimental evaluation of an automatic procedure for sensor fault detection and identification in a real process under closed-loop control is the objective of the present research. The scheme proposed here is very robust to faults in the main sensors of a multiloop control system, thus improving safety and reliability of plant operations. A state variable transformation is carried out in order to derive a model suitable for Recursive Least Squares (RLS) identification valid for all regimes of operation. The fault detection method is based on a moving window statistical analysis of the estimated model parameters. Simultaneously, a state estimation scheme, based on the Extended Kalman Filter (EKF), enables the fault identification, reduces false alarms and provides redundant measurements for alternative control purposes. Experimental runs were carried out in an industrial-scale pilot plant. Despite the large number of uncertainties and nonlinearities in the process, the system exhibited a good performance when faults occurred in the sensors of the control loops. | en_US |
dc.description.uri | http://www.sciencedirect.com/science/article/B8JGF-4RV2MNN-8/1/ebe82a5fae5921f13401727097dfa535 | en_US |
dc.format.mimetype | aplication/PDF | en |
dc.language.iso | eng | eng |
dc.rights | openAccess | eng |
dc.subject | fault detection | en_US |
dc.subject | fault identification | en_US |
dc.subject | fault tolerant control systems | en_US |
dc.subject | industrial control | en_US |
dc.title | Sensor Fault Detection and Identification in a Pilot Plant Under Process Control | en_US |
dc.type | article | en_US |
dc.identifier.doi | 10.1205/026387698525117 | - |
item.fulltext | Com Texto completo | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
item.openairetype | article | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
Appears in Collections: | FCTUC Eng.Química - Artigos em Revistas Internacionais |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
file594c1dd9f56a4b6dab324967bc9af523.pdf | 589.88 kB | Adobe PDF | View/Open |
SCOPUSTM
Citations
11
checked on Oct 7, 2024
WEB OF SCIENCETM
Citations
8
checked on Oct 2, 2024
Page view(s)
308
checked on Oct 15, 2024
Download(s)
361
checked on Oct 15, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.