Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/27897
DC FieldValueLanguage
dc.contributor.authorLou, Tiejiong-
dc.contributor.authorLopes, Sérgio M. R.-
dc.contributor.authorLopes, Adelino V.-
dc.date.accessioned2014-12-15T14:32:00Z-
dc.date.available2014-12-15T14:32:00Z-
dc.date.issued2014-10-
dc.identifier.citationLOU, Tiejiong; LOPES, Sergio M. R.; LOPES, Adelino V. - Flexure of continuous HSC beams with external CFRP tendons: effects of fibre elastic modulus and steel ratio. "Composite Structures". ISSN 0263-8223. Vol. 116 (2014) p. 29–37por
dc.identifier.issn0263-8223-
dc.identifier.urihttps://hdl.handle.net/10316/27897-
dc.description.abstractThe results of a theoretical study on the flexural behaviour of continuous high-strength concrete (HSC) beams prestressed with external fibre reinforced polymer (FRP) tendons are presented. A previously developed numerical model is extended to the analysis of continuous HSC beams with external FRP tendons. A numerical test is conducted on two-span externally prestressed beams made of HSC with compressive strength of 90 MPa. The external tendons are assumed to be carbon FRP (CFRP) composites covering a wide range of modulus of elasticity. Various levels of nonprestressed steel ratio are used. Comprehensive aspects of behaviour of such type of beams are examined. The results show that CFRP with high elastic modulus of 500 GPa mobilizes quite different structural responses compared to those with normal elastic modulus, and that the amount of nonprestressed steel affects remarkably the behaviour of such beams. The study also indicates that some moment redistribution knowledge valid for conventional continuous concrete beams may not be applicable to continuous HSC beams with external FRP tendons.por
dc.language.isoengpor
dc.publisherElsevierpor
dc.rightsopenAccesspor
dc.subjectContinuous beampor
dc.subjectExternal prestressingpor
dc.subjectFlexural behaviourpor
dc.subjectFibre reinforced polymerpor
dc.subjectHigh-strength concretepor
dc.titleFlexure of continuous HSC beams with external CFRP tendons: effects of fibre elastic modulus and steel ratiopor
dc.typearticlepor
degois.publication.firstPage29por
degois.publication.lastPage37por
degois.publication.titleComposite Structurespor
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S0263822314002013por
dc.peerreviewedYespor
dc.identifier.doi10.1016/j.compstruct.2014.05.001-
degois.publication.volume116por
uc.controloAutoridadeSim-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.openairetypearticle-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
crisitem.author.researchunitCEMMPRE - Centre for Mechanical Engineering, Materials and Processes-
crisitem.author.researchunitCEMMPRE - Centre for Mechanical Engineering, Materials and Processes-
crisitem.author.researchunitCentre for Research in Construction Science-
crisitem.author.orcid0000-0001-9150-1203-
crisitem.author.orcid0000-0002-8101-7095-
crisitem.author.orcid0000-0001-5092-4891-
Appears in Collections:I&D CEMMPRE - Artigos em Revistas Internacionais
FCTUC Eng.Civil - Artigos em Revistas Internacionais
Files in This Item:
Show simple item record

SCOPUSTM   
Citations

14
checked on Apr 15, 2024

WEB OF SCIENCETM
Citations 5

14
checked on Apr 2, 2024

Page view(s)

341
checked on Apr 23, 2024

Download(s) 50

426
checked on Apr 23, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.