dc.identifier.citationAPÓSTOLO, Ana Sofia Carvalho - Arejamento e elevação em sistemas de saneamento por injecção de ar comprimido. Coimbra : [s.l.], 2011. Dissertação de mestrado. Disponível na WWW: http://hdl.handle.net/10316/23595.-
dc.identifier.urihttps://hdl.handle.net/10316/23595-
dc.descriptionDissertação de mestrado em Engenharia Civil (Hidráulica, Recursos Hídricos e Ambiente) apresentada à Faculdade de Ciências e Tecnologia da Universidade de Coimbrapor
dc.description.abstractA aplicação da técnica de bombagem Air-lift nas mais diversas áreas suscitou o interesse da sua aplicação a sifões invertidos já que, não só pela substituição de mecanismos elevatórios convencionais, permite um arejamento da massa líquida solucionando assim alguns das condicionantes do escoamento de águas residuais em sifões invertidos. No seguimento de trabalhos anteriores, particularmente Diogo e Oliveira (2008), Oliveira (2009) e Diogo e Gomes (2011) e em desenvolvimento Diogo and Oliveira, e com base no princípio que define a técnica de elevação por injecção de ar, esta tese centra-se no estudo do escoamento bifásico água-ar, pretendendo-se quantificar experimentalmente as principais vantagens em termos de carga hidráulica que a técnica poderá apresentar quando aplicada a sifões. O trabalho experimental decorreu na instalação construída no LHRHA do DEC-UC e consiste num sifão com dois ramos em paralelo, de diâmetros 35 e 110 mm, com funcionamento alternado nos quais se processa um escoamento bifásico no ramo ascendente. O desempenho da bombagem por injecção de ar foi estudado para diferentes velocidades de escoamento.por
dc.description.abstractThe application of the Air-lift pumping technique in several areas has raised the interest of its application to inverted siphons since, not only by the replacement of conventional lift mechanisms, aerates the liquid mass thus solving some of the conditions of the sewage disposal in inverted siphons. Following previous works, particularly Diogo and Oliveira (2008), Oliveira (2009) and Gomes and Diogo (2011) and in progress Diogo Oliveira, and based on the principle that defines the air injection lifting technique, this thesis focuses on the study of the air-water twophase flow, which seeks to experimentally quantify the major advantages in terms of hydraulic load may make the technique when applied to siphons. The experimental work took place at the facility built in the LHRHA DEC-UC and consists of a siphon with two branches in parallel, with a diameter 35 and 110 mm, with alternate function which takes place in a two-phase flow in the ascending tube. The performance of the air injection pump has been studied for different flow velocities.por
dc.language.isoporpor
dc.rightsopenAccesspor
dc.subjectEscoamento bifásicopor
dc.subjectSifãopor
dc.subjectBombagempor
dc.titleArejamento e elevação em sistemas de saneamento por injecção de ar comprimidopor
dc.typemasterThesispor
dc.peerreviewedYespor
item.fulltextCom Texto completo-
item.languageiso639-1pt-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypemasterThesis-
item.grantfulltextopen-
item.cerifentitytypePublications-
Appears in Collections:UC - Dissertações de Mestrado
FCTUC Eng.Civil - Teses de Mestrado
Files in This Item:
File Description SizeFormat
tese AnA Apostolo.pdfDissertação855.75 kBAdobe PDFView/Open
ANEXO ana apostolo2002105093.pdfAnexo97.13 kBAdobe PDFView/Open
Show simple item record

Page view(s)

258
checked on Jul 23, 2024

Download(s) 50

367
checked on Jul 23, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.