Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/114155
Title: Assessing MR-compatibility of somatosensory stimulation devices: A systematic review on testing methodologies
Authors: Travassos, Carolina
Sayal, Alexandre 
Direito, Bruno 
Pereira, João
Sousa, Teresa
Castelo-Branco, Miguel 
Keywords: MR-compatible; MR-safe; compatibility; functional MRI (fMRI); magnetic resonance imaging (MRI); safety; somatosensory stimulation devices
Issue Date: 2023
Serial title, monograph or event: Frontiers in Neuroscience
Volume: 17
Abstract: Functional magnetic resonance imaging (fMRI) has been extensively used as a tool to map the brain processes related to somatosensory stimulation. This mapping includes the localization of task-related brain activation and the characterization of brain activity dynamics and neural circuitries related to the processing of somatosensory information. However, the magnetic resonance (MR) environment presents unique challenges regarding participant and equipment safety and compatibility. This study aims to systematically review and analyze the state-of-the-art methodologies to assess the safety and compatibility of somatosensory stimulation devices in the MR environment. A literature search, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement guidelines, was performed in PubMed, Scopus, and Web of Science to find original research on the development and testing of devices for somatosensory stimulation in the MR environment. Nineteen records that complied with the inclusion and eligibility criteria were considered. The findings are discussed in the context of the existing international standards available for the safety and compatibility assessment of devices intended to be used in the MR environment. In sum, the results provided evidence for a lack of uniformity in the applied testing methodologies, as well as an in-depth presentation of the testing methodologies and results. Lastly, we suggest an assessment methodology (safety, compatibility, performance, and user acceptability) that can be applied to devices intended to be used in the MR environment.
URI: https://hdl.handle.net/10316/114155
ISSN: 1662-4548
DOI: 10.3389/fnins.2023.1071749
Rights: openAccess
Appears in Collections:I&D ICNAS - Artigos em Revistas Internacionais
I&D CIBIT - Artigos em Revistas Internacionais
FMUC Medicina - Artigos em Revistas Internacionais

Show full item record

Page view(s)

7
checked on Apr 24, 2024

Download(s)

7
checked on Apr 24, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons