Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/112216
Title: Lossy Image Compression in a Preclinical Multimodal Imaging Study
Authors: Cunha, Francisco F. 
Blüml, Valentin
Zopf, Lydia M.
Walter, Andreas
Wagner, Michael
Weninger, Wolfgang J.
Thomaz, Lucas A.
Tavora, Luís M. N.
Cruz, Luís A. da Silva 
Faria, Sergio M. M.
Keywords: Biomedical imaging; Image coding; Image segmentation; Performance evaluation
Issue Date: 2023
Publisher: Springer Nature
Project: COST Action CA17121 (www. comul is. eu), supported by COST (European Cooperation in Science and Technology) 
UIDB/50008/2020 
LA/P/0109/2020 
FCT - project CIBME 
Serial title, monograph or event: Journal of Digital Imaging
Volume: 36
Issue: 4
Abstract: The growing use of multimodal high-resolution volumetric data in pre-clinical studies leads to challenges related to the management and handling of the large amount of these datasets. Contrarily to the clinical context, currently there are no standard guidelines to regulate the use of image compression in pre-clinical contexts as a potential alleviation of this problem. In this work, the authors study the application of lossy image coding to compress high-resolution volumetric biomedical data. The impact of compression on the metrics and interpretation of volumetric data was quantified for a correlated multimodal imaging study to characterize murine tumor vasculature, using volumetric high-resolution episcopic microscopy (HREM), micro-computed tomography (μCT), and micro-magnetic resonance imaging (μMRI). The effects of compression were assessed by measuring task-specific performances of several biomedical experts who interpreted and labeled multiple data volumes compressed at different degrees. We defined trade-offs between data volume reduction and preservation of visual information, which ensured the preservation of relevant vasculature morphology at maximum compression efficiency across scales. Using the Jaccard Index (JI) and the average Hausdorff Distance (HD) after vasculature segmentation, we could demonstrate that, in this study, compression that yields to a 256-fold reduction of the data size allowed to keep the error induced by compression below the inter-observer variability, with minimal impact on the assessment of the tumor vasculature across scales.
URI: https://hdl.handle.net/10316/112216
ISSN: 1618-727X
DOI: 10.1007/s10278-023-00800-5
Rights: openAccess
Appears in Collections:I&D IT - Artigos em Revistas Internacionais
FCTUC Eng.Electrotécnica - Artigos em Revistas Internacionais

Show full item record

Page view(s)

39
checked on Apr 24, 2024

Download(s)

24
checked on Apr 24, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons