Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/112204
Título: The triggerless data acquisition system of the XENONnT experiment
Autor: Cardoso, J. 
Lopes, J. 
Santos, J. M. F. dos 
Silva, M. 
XENON collaboration
Palavras-chave: Dark Matter detectors (WIMPs, axions, etc.); Data acquisition concepts; Data processing methods; Front-end electronics for detector readout
Data: Jul-2023
Editora: Institute of Physics Publishing
Título da revista, periódico, livro ou evento: Journal of Instrumentation
Volume: 18
Número: 7
Resumo: The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commercially available hardware accompanied by open-source and custom-developed software. The three constituent subsystems of the XENONnT detector, the TPC (main detector), muon veto, and the newly introduced neutron veto, are integrated into a single DAQ, and can be operated both independently and as a unified system. In total, the DAQ digitizes the signals of 698 photomultiplier tubes (PMTs), of which 253 from the top PMT array of the TPC are digitized twice, at ×10 and ×0.5 gain. The DAQ for the most part is a triggerless system, reading out and storing every signal that exceeds the digitization thresholds. Custom-developed software is used to process the acquired data, making it available within ∼ 30 s for live data quality monitoring and online analyses. The entire system with all the three subsystems was successfully commissioned and has been operating continuously, comfortably withstanding readout rates that exceed ∼ 500 MB/s during calibration. Livetime during normal operation exceeds 99% and is ∼ 90% during most high-rate calibrations. The combined DAQ system has collected more than 2 PB of both calibration and science data during the commissioning of XENONnT and the first science run.
URI: https://hdl.handle.net/10316/112204
DOI: 10.1088/1748-0221/18/07/P07054
Direitos: openAccess
Aparece nas coleções:FCTUC Física - Artigos em Revistas Internacionais
LIBPhys - Artigos em Revistas Internacionais

Ficheiros deste registo:
Mostrar registo em formato completo

Visualizações de página

39
Visto em 17/jul/2024

Downloads

34
Visto em 17/jul/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons