Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/112072
Título: The CYGNO experiment, a directional detector for direct Dark Matter searches
Autor: Amaro, F. D. 
Baracchini, E.
Benussi, L.
Bianco, S.
Capoccia, C.
Caponero, M.
Cardoso, D. S.
Cavoto, G.
Cortez, A.
Costa, I. A.
Dané, E.
Dho, G.
Di Giambattista, F.
Di Marco, E.
D'Imperio, G.
Iacoangeli, F
Jùnior, H. P. L.
Lopes, G. S. P.
Maccarrone, G.
Mano, R.D.P. 
Gregorio, R. R. M.
Marques, D. J. G.
Mazzitelli, G.
McLean, A. G.
Messina, A.
Monteiro, C. M. B. 
Nobrega, R. A.
Pains, I. F.
Paoletti, E.
Passamonti, L.
Pelosi, S.
Petrucci, F.
Piacentini, S.
Piccolo, D.
Pierluigi, D.
Pinci, D.
Prajapati, A.
Renga, F.
Roque, R. J. C. 
Rosatelli, F.
Russo, A.
Santos, J. M. F. dos 
Saviano, G.
Spooner, N. J. C.
Tesauro, R.
Tomassini, S.
Torelli, S.
Palavras-chave: Dark matter; Time projection chamber; Optical readout
Data: 7-Jun-2023
Editora: Elsevier
Projeto: European Union’s Horizon 2020 research and innovation programme under the ERC Consolidator Grant Agreement No 818744. 
Título da revista, periódico, livro ou evento: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume: 1054
Resumo: The CYGNO project aims at the development of a high precision optical readout gaseous Tima Projection Chamber (TPC) for directional dark matter (DM) searches, to be hosted at Laboratori Nazionali del Gran Sasso (LNGS). CYGNO employs a He:CF$_4$ gas mixture at atmospheric pressure with a Gas Electron Multiplier (GEM) based amplification structure coupled to an optical readout comprised of sCMOS cameras and photomultiplier tubes (PMTs). This experimental setup allows to achieve 3D tracking and background rejection down to O(1) keV energy, to boost sensitivity to low WIMP masses. The characteristics of the optical readout approach in terms of the light yield will be illustrated along with the particle identification properties. The project timeline foresees, in the next 2-3 years, the realisation and installation of a 0.4 m$^3$ TPC in the underground laboratories at LNGS to act as a demonstrator. Finally, the studies of the expected DM sensitivities of the CYGNO demonstrator will be presented.
URI: https://hdl.handle.net/10316/112072
ISSN: 01689002
DOI: 10.1016/j.nima.2023.168325
Direitos: openAccess
Aparece nas coleções:FCTUC Física - Artigos em Revistas Internacionais
LIBPhys - Artigos em Revistas Internacionais

Ficheiros deste registo:
Mostrar registo em formato completo

Visualizações de página

38
Visto em 8/mai/2024

Downloads

23
Visto em 8/mai/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.