Title: Fuel cells operating as an immunosensor for cancer biomarker screening
Authors: Ferreira, Nádia
Carneiro, Liliana
Pinto, Alexandra M. F. R.
Sales, M. Goreti F. 
Keywords: Immunosensor; Direct methanol fuel cell; CA15-3; Cancer biomarker; Point-of-care
Issue Date: 2023
Publisher: Elsevier
Project: The authors gratefully acknowledge the financial support of European Commission (FET-Open/H2020-Symbiotic/GA665046). N´adia S. Ferreira (Grant reference SFRH/BD/122955/2016), Liliana P. T. Carneiro (Grant reference SFRH/BD/122954/2016) and CEFT (UIDB/ 00532/2021 and UIDP/00532/2021) acknowledge Fundaç˜ao para a Ciˆencia e Tecnologia for financial support. 
Serial title, monograph or event: Biosensors and Bioelectronics: X
Volume: 14
Abstract: This work presents the first integration of antibodies into one of the electrodes of a passive direct methanol fuel cell (DMFC) to create an autonomous immunosensor for cancer antigen 15–3 (CA15-3). The anode of the fuel cell was first made of carbon cloth with carbon black, platinum and ruthenium nanoparticles and then modified with anti-CA15-3, while the cathode was made of carbon cloth with carbon black and platinum nanoparticles. This hybrid DMFC (hDMFC), which works as an immunosensor, was fed with dilute methanol to generate a concentration-dependent current. The hDMFC device was calibrated in different media (buffer and serum), by incubating increasing concentrations of CA15-3 standard solutions, ranging from 47 to 750 U/mL. The linear response ranged from 188 to 563 U/mL, and the limit of detection (LoD) was 39.8 U/mL. The selectivity of the biosensor was also evaluated with competing cancer biomarkers, such as carcinoembryonic antigen (CEA), and cancer antigen 125 (CA-125), as well as with other compounds normally present in blood plasma (ascorbic acid, glucose, uric acid and urea), adjusted to the normal range of concentrations in serum. The results obtained indicate good selectivity of the immunosensor in the fuel cell. In general, the immunosensor showed a good response considering its integration into a passive DMFC. It is a good sensor for point-of-care (PoC) diagnosis because it has a good performance in human serum and, most importantly, it pursues electrical autonomy.
URI: https://hdl.handle.net/10316/111944
ISSN: 25901370
DOI: 10.1016/j.biosx.2023.100344
Rights: openAccess
Appears in Collections:FCTUC Eng.Química - Artigos em Revistas Internacionais

Files in This Item:
Show full item record

Page view(s)

18
checked on Apr 24, 2024

Download(s)

13
checked on Apr 24, 2024

Google ScholarTM

Check

Altmetric

Altmetric


This item is licensed under a Creative Commons License Creative Commons