Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/111919
Título: Coamorphous Systems of Valsartan: Thermal Analysis Contribution to Evaluate Intermolecular Interactions Effects on the Structural Relaxation
Autor: Ekawa, Bruno
Diogo, Hermínio P
Castro, Ricardo A. E. 
Caires, Flávio J
Eusébio, M. Ermelinda S. 
Palavras-chave: valsartan; coamorphous; glass transition; isoconversional kinetic; TSDC
Data: 25-Ago-2023
Editora: MDPI
Projeto: This research was funded by FAPESP (Grant no. 2018/24378-6), CNPq (Grant nos. 422893/2021-8 and 317282/2021-2), CAPES PrInt (Grant no. 88887.582123/2020-00), and FCT, Portugal, Project UID/QUI/00313/2020. Part of this work was supported by FCT, Portugal, Projects UIDB/00100/2020, UIDP/00100/2020, and IMS-LA/P/0056/2020UIDB/00100/2020. 
Título da revista, periódico, livro ou evento: Molecules
Volume: 28
Número: 17
Resumo: Coamorphous formation in binary systems of valsartan (Val) with 4,4'-bipyridine (Bipy) and trimethoprim (Tri) was investigated for mixtures with a mole fraction of 0.16~0.86 of valsartan and evaluated in terms of the glass transition temperature. The glass transition of the systems had a behavior outside the values predicted by the Gordon-Taylor equation, showing that Val-Bipy (hydrogen bonding between the components) had a lower deviation and Val-Tri (ionic bonding between the components) had a higher deviation. Mixtures of compositions 2:1 Val-Bipy and 1:1 Val-Tri were selected for further investigation and verified to be stable, as no crystallization was observed during subsequent heating and cooling programs. For these systems, the effective activation energy during glass transition was evaluated. Compared to pure valsartan, the system with the lower glass transition temperature (Val-Bipy) presented the highest effective activation energy, and the system with the higher glass transition temperature (Val-Tri) presented a lower effective activation energy. The results presented a good correlation between the data obtained from two different techniques to determine the fragility and effective activation energy: non-isothermal kinetic analysis by DSC and TSDC.
URI: https://hdl.handle.net/10316/111919
ISSN: 1420-3049
DOI: 10.3390/molecules28176240
Direitos: openAccess
Aparece nas coleções:FCTUC Química - Artigos em Revistas Internacionais
I&D CQC - Artigos em Revistas Internacionais

Mostrar registo em formato completo

Visualizações de página

39
Visto em 8/mai/2024

Downloads

24
Visto em 8/mai/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons