Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/108670
Título: New results on low-mass dark matter from the CRESST-II experiment
Autor: Petricca, F. 
Angloher, G. 
Bento, A. 
Bucci, C. 
Canonica, L.
Defay, X.
Erb, A. 
v Feilitzsch, F.
Ferreiro Iachellini, N.
Gorla, P.
Gütlein, A. 
Hauff, D. 
Jochum, J. 
Kiefer, M. 
Kluck, H.
Kraus, H.
Lanfranchi, J.-C. 
Loebell, J.
Münster, A. 
Pagliarone, C.
Potzel, W. 
Pröbst, F. 
Reindl, F. 
Schäffner, K. 
Schieck, J.
Schönert, S. 
Seidel, W. 
Stodolsky, L. 
Strandhagen, C. 
Strauß, R. 
Tanzke, A. 
Trinh Thi, H. H.
Türkoğlu, C.
Uffinger, M.
Ulrich, A. 
Usherov, I. 
Wawoczny, S. 
Willers, M. 
Wüstrich, M.
Zöller, A. 
Data: 2016
Editora: Institute of Physics Publishing
Projeto: We are grateful to LNGS for their generous support of CRESST, in particular to Marco Guetti for his constant assistance. This work was supported by the DFG cluster of excellence: Origin and Structure of the Universe, by the Helmholtz Alliance for Astroparticle Physics, and by the BMBF: Project 05A11WOC EURECA-XENON. 
Título da revista, periódico, livro ou evento: Journal of Physics: Conference Series
Volume: 718
Número: 4
Resumo: The CRESST-II experiment is searching for dark matter particles via their elastic scattering off nuclei in a target material. The CRESST target consists of scintillating CaWO4 crystals which are operated as cryogenic calorimeters at millikelvin temperatures and read out by transition edge sensors. Each interaction in the CaWO4 target crystal produces a phonon signal and also a light signal that is measured by a secondary cryogenic calorimeter. The low energy thresholds of these detectors, combined with the presence of light nuclei in the target material, allow to probe the low-mass region of the parameter space for spin-independent dark matter-nucleon scattering with high sensitivity. In this contribution results from a blind analysis of one detector module operated in the latest measurement campaign are presented. An unprecedented sensitivity for the light dark matter has been obtained with 52kg live days and a threshold of 307eV for nuclear recoils, extending the reach of direct dark matter searches to the sub-GeV/c2 region.
URI: https://hdl.handle.net/10316/108670
ISSN: 1742-6588
1742-6596
DOI: 10.1088/1742-6596/718/4/042044
Direitos: openAccess
Aparece nas coleções:FCTUC Física - Artigos em Revistas Internacionais

Ficheiros deste registo:
Mostrar registo em formato completo

Visualizações de página

48
Visto em 24/jul/2024

Downloads

8
Visto em 24/jul/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons