Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/107029
Título: Impact of an Innovative Securement Dressing and Tourniquet in Peripheral Intravenous Catheter-Related Complications and Contamination: An Interventional Study
Autor: Parreira, Pedro 
Serambeque, Beatriz 
Costa, Paulo S.
Mónico, Lisete 
Oliveira, Vânia
Sousa, Liliana B. 
Gama, Fernando
Bernardes, Rafael A.
Adriano, David
Marques, Inês A. 
Braga, Luciene M.
Graveto, João
Osório, Nádia Isabel Almeida 
Salgueiro-Oliveira, Anabela
Palavras-chave: catheter-related bloodstream infections; complications; contamination; infection prevention; nursing; occlusive dressings
Data: 8-Set-2019
Editora: MDPI
Projeto: “Transfer of technological innovations to nursing practice: a contribution to the prevention of infections” project (CENTRO-01-0145-FEDER-024371), funded by the European Regional Development Fund—FEDER—through the Competitiveness and Internationalization Operational Program of PORTUGAL 2020 
Título da revista, periódico, livro ou evento: International Journal of Environmental Research and Public Health
Volume: 16
Número: 18
Resumo: Reusable tourniquets and conventional securement dressings are considered risk factors for the occurrence of reported complications and catheter-related bloodstream infections. This study's purpose is to assess the impact of single-use disposable tourniquets and advanced occlusive polyurethane dressings with reinforced cloth borders on peripheral intravenous catheter (PIVC)-related complications and contamination. A pre- and post-interventional prospective observational study was conducted in a cardiology ward of a tertiary hospital between April 2018 and February 2019. Overall, demographic and clinical data from 156 patients and PIVC-related outcomes were collected (n = 296) as well as PIVC tips for microbiological analysis (n = 90). In the pre-intervention phase (n = 118), complication rates of 62.1% were reported, while 44.1% of the PIVCs were contaminated (n = 34). In the post-intervention phase (n = 178), complication rates decreased to 57.3%, while contamination rates significantly decreased to 17.9% (p = 0.014; n = 56). Through a logistic regression, it was found that the use of innovative technologies reduces the chance of PIVC contamination by 79% (odds ratio (OR): 0.21; 95% confidence interval (CI): 0.05-0.98; p = 0.046). Meanwhile, PIVC-related complications and fluid therapy emerged as predictors for PIVC contamination. Findings suggest that the adoption of these innovative devices in nurses' practice contributes to the significant reduction of PIVC contamination.
URI: https://hdl.handle.net/10316/107029
ISSN: 1660-4601
DOI: 10.3390/ijerph16183301
Direitos: openAccess
Aparece nas coleções:FPCEUC - Artigos em Revistas Internacionais

Mostrar registo em formato completo

Citações SCOPUSTM   

11
Visto em 6/mai/2024

Citações WEB OF SCIENCETM

9
Visto em 2/mai/2024

Visualizações de página

42
Visto em 7/mai/2024

Downloads

14
Visto em 7/mai/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons