Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/103771
Título: Plastic Antibody of Polypyrrole/Multiwall Carbon Nanotubes on Screen-Printed Electrodes for Cystatin C Detection
Autor: Gomes, Rui S. 
Gomez-Rodríguez, Blanca Azucena
Fernandes, Ruben
Sales, M. Goreti F. 
Moreira, Felismina T C 
Dutra, Rosa F.
Palavras-chave: cystatin C; molecularly imprinted polymer; electrochemical biosensor; polypyrene; multiwall carbon nanotubes; acute kidney injury
Data: 31-Mai-2021
Editora: MDPI
Projeto: 0624_2IQBIONEURO_6_E 
CNPQ (National Council for Scientific and Technological Development, Brazil) grant number 440605/2016-4 
FCT - Grant number SAICT-POL/24325/2016. 
Título da revista, periódico, livro ou evento: Biosensors
Volume: 11
Número: 6
Resumo: This work reports the design of a novel plastic antibody for cystatin C (Cys-C), an acute kidney injury biomarker, and its application in point-of-care (PoC) testing. The synthetic antibody was obtained by tailoring a molecularly imprinted polymer (MIP) on a carbon screen-printed electrode (SPE). The MIP was obtained by electropolymerizing pyrrole (Py) with carboxylated Py (Py-COOH) in the presence of Cys-C and multiwall carbon nanotubes (MWCNTs). Cys-C was removed from the molecularly imprinted poly(Py) matrix (MPPy) by urea treatment. As a control, a non-imprinted poly(Py) matrix (NPPy) was obtained by the same procedure, but without Cys-C. The assembly of the MIP material was evaluated in situ by Raman spectroscopy and the binding ability of Cys-C was evaluated by the cyclic voltammetry (CV) and differential pulse voltammetry (DPV) electrochemical techniques. The MIP sensor responses were measured by the DPV anodic peaks obtained in the presence of ferro/ferricyanide. The peak currents decreased linearly from 0.5 to 20.0 ng/mL of Cys-C at each 20 min successive incubation and a limit of detection below 0.5 ng/mL was obtained at pH 6.0. The MPPy/SPE was used to analyze Cys-C in spiked serum samples, showing recoveries <3%. This device showed promising features in terms of simplicity, cost and sensitivity for acute kidney injury diagnosis at the point of care.
URI: https://hdl.handle.net/10316/103771
ISSN: 2079-6374
DOI: 10.3390/bios11060175
Direitos: openAccess
Aparece nas coleções:FCTUC Eng.Química - Artigos em Revistas Internacionais

Mostrar registo em formato completo

Citações SCOPUSTM   

14
Visto em 30/set/2024

Citações WEB OF SCIENCETM

15
Visto em 2/out/2024

Visualizações de página

92
Visto em 1/out/2024

Downloads

40
Visto em 1/out/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons