Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/103499
Título: Automated Lung Sound Classification Using a Hybrid CNN-LSTM Network and Focal Loss Function
Autor: Petmezas, Georgios
Cheimariotis, Grigorios-Aris
Stefanopoulos, Leandros
Rocha, Bruno 
Paiva, Rui Pedro 
Katsaggelos, Aggelos K.
Maglaveras, Nicos
Palavras-chave: lung sounds; crackles; wheezes; STFT; CNN; LSTM; focal loss; COPD; asthma
Data: 6-Fev-2022
Editora: MDPI
Projeto: EU-WELMO project (project number 210510516) 
Ph.D. scholarship SFRH/BD/135686/2018 
Ph.D. scholarship 2020.04927.BD 
Título da revista, periódico, livro ou evento: Sensors
Volume: 22
Número: 3
Resumo: Respiratory diseases constitute one of the leading causes of death worldwide and directly affect the patient's quality of life. Early diagnosis and patient monitoring, which conventionally include lung auscultation, are essential for the efficient management of respiratory diseases. Manual lung sound interpretation is a subjective and time-consuming process that requires high medical expertise. The capabilities that deep learning offers could be exploited in order that robust lung sound classification models can be designed. In this paper, we propose a novel hybrid neural model that implements the focal loss (FL) function to deal with training data imbalance. Features initially extracted from short-time Fourier transform (STFT) spectrograms via a convolutional neural network (CNN) are given as input to a long short-term memory (LSTM) network that memorizes the temporal dependencies between data and classifies four types of lung sounds, including normal, crackles, wheezes, and both crackles and wheezes. The model was trained and tested on the ICBHI 2017 Respiratory Sound Database and achieved state-of-the-art results using three different data splitting strategies-namely, sensitivity 47.37%, specificity 82.46%, score 64.92% and accuracy 73.69% for the official 60/40 split, sensitivity 52.78%, specificity 84.26%, score 68.52% and accuracy 76.39% using interpatient 10-fold cross validation, and sensitivity 60.29% and accuracy 74.57% using leave-one-out cross validation.
URI: https://hdl.handle.net/10316/103499
ISSN: 1424-8220
DOI: 10.3390/s22031232
Direitos: openAccess
Aparece nas coleções:I&D CISUC - Artigos em Revistas Internacionais

Ficheiros deste registo:
Mostrar registo em formato completo

Citações SCOPUSTM   

59
Visto em 15/abr/2024

Citações WEB OF SCIENCETM

33
Visto em 2/abr/2024

Visualizações de página

78
Visto em 23/abr/2024

Downloads

117
Visto em 23/abr/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Este registo está protegido por Licença Creative Commons Creative Commons