Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/8533
DC FieldValueLanguage
dc.contributor.advisorCorreia, Carlos M.-
dc.contributor.advisorFerreira, Luís Requicha-
dc.contributor.authorPereira, Helena Catarina de Bastos Marques-
dc.date.accessioned2009-02-04T14:05:39Z-
dc.date.available2009-02-04T14:05:39Z-
dc.date.issued2007-09-
dc.identifier.urihttps://hdl.handle.net/10316/8533-
dc.descriptionRelatório de projecto do 5º ano de Engenharia Biomédicaen_US
dc.description.abstractIn the past recent years, great emphasis has been placed on the role of arterial stiffness in the development of cardiovascular diseases, recognized as the leading cause of death in the world. This hemodynamic parameter, generally associated to age and blood pressure increase, can be assessed by the measurement of the pulse wave velocity (PWV), i.e., the velocity at which the pressure wave propagates along an artery. Although PWV measurement is accepted as the most simple, non-invasive, robust and reproducible method to determine arterial stiffness over the carotid-femoral region, the devices available in the market for this purpose are extremely expensive. This research project aims at developing alternative instrumental methods for the aortic PWV’s hemodynamic characterization and, at a later stage, a software application for acquisition and interpretation of this information. The proposed instruments are constituted by one accelerometric probe and a multisensor acquisition module, which includes classic electrodes of electrocardiography, piezoelectric (PZ) transducers and, foreseen, one pressure sensor. Up to now, in its research usage, it has proved effective in the prolonged follow up of hypertensive patients without and with drug treatment, allowing the study of correlations between the different types of signals. A valuable contribution to this study has been given by the bench models developed in laboratory for the ADXL203 accelerometer calibration and pulsatory system simulation. This report describes not only the aspects related with the overall instrument architecture, the successive developed versions and the results obtained, under medical control, for each of the input signals, but also the calibration and pulsatory models and respective results.-
dc.language.isoengen_US
dc.rightsopenAccesseng
dc.subjectAcelerómetroen_US
dc.subjectVelocidade de onda de pulsoen_US
dc.subjectDoenças cardiovascularesen_US
dc.subjectMódulo de aquisição multisensoren_US
dc.titleCardioaccelerometery: the assessment of pulse wave velocity using accelerometersen_US
dc.typereporten_US
item.openairecristypehttp://purl.org/coar/resource_type/c_93fc-
item.openairetypereport-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.advisor.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.advisor.parentresearchunitUniversity of Coimbra-
crisitem.advisor.orcid0000-0002-0527-3206-
crisitem.author.orcid0000-0002-1423-3038-
Appears in Collections:FCTUC Física - Vários
Files in This Item:
File Description SizeFormat
HelenaCBMPereira_Est.pdf1.83 MBAdobe PDFView/Open
Show simple item record

Page view(s)

253
checked on Apr 23, 2024

Download(s)

202
checked on Apr 23, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.