Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/8474
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Donato, P. | - |
dc.contributor.author | Coelho, P. | - |
dc.contributor.author | Rodrigues, H. | - |
dc.contributor.author | Vigia, E. | - |
dc.contributor.author | Fernandes, J. | - |
dc.contributor.author | Caseiro-Alves, F. | - |
dc.contributor.author | Bernardes, A. | - |
dc.date.accessioned | 2009-02-17T10:50:20Z | - |
dc.date.available | 2009-02-17T10:50:20Z | - |
dc.date.issued | 2007 | en_US |
dc.identifier.citation | Surgical and Radiologic Anatomy. 29:7 (2007) 575-582 | en_US |
dc.identifier.uri | https://hdl.handle.net/10316/8474 | - |
dc.description.abstract | Abstract Due to constant innovations in radiological and surgical techniques, more accurate results are expected in the diagnostic and therapeutic procedures related to hepatic pathology. The aim of this work was to demonstrate the normal hepatic vascular and biliary anatomy using cadaveric livers and CT scans of the affected livers. Furthermore, using the CT scans, the authors intended to illustrate the most common morphological variations of the vascular and biliary anatomy. Four human cadaveric livers were injected with colored silicone mixed with radiological contrast solution in the common bile duct, in the proper hepatic artery, in the portal vein and in the inferior vena cava near the ostia of the hepatic veins (only one of these structures was injected in each liver). After obtaining the CT scans, 3D rendered models were created, which demonstrated the normal hepatic anatomy of the vascular and biliary structures. The International Anatomical Nomenclature was used for their classification (based on Couinaud’s work). The 3D rendered CT models were also modified to illustrate the most common normal variations of the hepatic anatomy (found in the literature). | en_US |
dc.language.iso | eng | eng |
dc.rights | openAccess | eng |
dc.title | Normal vascular and biliary hepatic anatomy: 3D demonstration by multidetector CT | en_US |
dc.type | article | en_US |
dc.identifier.doi | 10.1007/s00276-007-0233-1 | en_US |
item.fulltext | Com Texto completo | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
item.openairetype | article | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
crisitem.author.researchunit | CNC - Center for Neuroscience and Cell Biology | - |
crisitem.author.orcid | 0000-0001-9397-6149 | - |
Appears in Collections: | FMUC Medicina - Artigos em Revistas Internacionais |
SCOPUSTM
Citations
14
checked on Oct 7, 2024
WEB OF SCIENCETM
Citations
5
14
checked on Oct 2, 2024
Page view(s) 50
580
checked on Oct 15, 2024
Download(s) 50
529
checked on Oct 15, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.