dc.description.abstractMercury-thin film electrodes coated with a thin film of poly(ester sulphonic acid) (PESA) have been investigated for application in the analysis of trace heavy metals by square wave anodic stripping voltammetry using the batch injection analysis (BIA) technique. Different polymer dispersion concentrations in water/acetone mixed solvent are investigated and are characterised by electrochemical impedance measurements on glassy carbon and on mercury film electrodes. The influence of electrolyte anion, acetate or nitrate, on polymer film properties is demonstrated, acetate buffer being shown to be preferable for stripping voltammetry applications. Although stripping currents are between 30 and 70% less at the coated than at bare mercury thin film electrodes, the influence of model surfactants on stripping response is shown to be very small. The effect of the composition of the modifier film dispersion on calibration plots is shown; however, detection limits of around 5 nM are found for all modified electrodes tested. This coated electrode is an alternative to Nafion-coated mercury thin film electrodes for the analysis of trace metals in complex matrices, particularly useful when there is a high concentration of non-ionic detergents.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6THP-3XX691V-B/1/0b3158737a56f528080be266d91c0dcben_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectPoly(ester sulphonic acid) modified electrodesen_US
dc.subjectMercury thin-film electrodeen_US
dc.subjectBatch injection analysisen_US
dc.subjectAnodic stripping voltammetryen_US
dc.titlePoly(ester sulphonic acid) coated mercury thin film electrodes: characterization and application in batch injection analysis stripping voltammetry of heavy metal ionsen_US
dc.typearticleen_US
dc.identifier.doi10.1016/S0039-9140(99)00232-5-
item.fulltextCom Texto completo-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
crisitem.author.orcid0000-0002-1972-4434-
Aparece nas coleções:FCTUC Química - Artigos em Revistas Internacionais
Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
file3bb37a25523d4562b89db74d38344414.pdf161.58 kBAdobe PDFVer/Abrir
Mostrar registo em formato simples

Citações SCOPUSTM   

62
Visto em 14/out/2024

Citações WEB OF SCIENCETM

58
Visto em 2/out/2024

Visualizações de página

323
Visto em 15/out/2024

Downloads

290
Visto em 15/out/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.