Please use this identifier to cite or link to this item: http://hdl.handle.net/10316/4559
Title: Rate and gain limitations of MSGCs and MGCs combined with GEM and other preamplification structures
Authors: Fonte, P. 
Peskov, V. 
Ramsey, B. D. 
Issue Date: 1998
Citation: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 419:2-3 (1998) 405-409
Abstract: We have studied the rate and gain limits of diamond-coated Microstrip Gas Counters (MSGCs) and Micro-Gap Counters (MGCs) when combined with various preamplification structures: Gas Electron Multiplier (GEM), Parallel-Plate Avalanche Chamber (PPAC) or a MICROMEGAS-type structure. Measurements were done both with X-rays and alpha particles with various detector geometries and in different gas mixtures at pressures from 0.05 to 10 atm.