Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/4425
DC FieldValueLanguage
dc.contributor.authorLudhova, L.-
dc.contributor.authorAmaro, F. D.-
dc.contributor.authorAntognini, A.-
dc.contributor.authorBiraben, F.-
dc.contributor.authorCardoso, J. M. R.-
dc.contributor.authorConde, C. A. N.-
dc.contributor.authorCovita, D. S.-
dc.contributor.authorDax, A.-
dc.contributor.authorDhawan, S.-
dc.contributor.authorFernandes, L. M. P.-
dc.contributor.authorHänsch, T. W.-
dc.contributor.authorHughes, V.-W.-
dc.contributor.authorHuot, O.-
dc.contributor.authorIndelicato, P.-
dc.contributor.authorJulien, L.-
dc.contributor.authorKnowles, P. E.-
dc.contributor.authorKottmann, F.-
dc.contributor.authorLopes, J. A. M.-
dc.contributor.authorLiu, Y.-W.-
dc.contributor.authorMonteiro, C. M. B.-
dc.contributor.authorMulhauser, F.-
dc.contributor.authorNez, F.-
dc.contributor.authorPohl, R.-
dc.contributor.authorRabinowitz, P.-
dc.contributor.authorSantos, J. M. F. dos-
dc.contributor.authorSchaller, L. A.-
dc.contributor.authorTaqqu, D.-
dc.contributor.authorVeloso, J. F. C. A.-
dc.date.accessioned2008-09-01T11:06:53Z-
dc.date.available2008-09-01T11:06:53Z-
dc.date.issued2005en_US
dc.identifier.citationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 540:1 (2005) 169-179en_US
dc.identifier.urihttps://hdl.handle.net/10316/4425-
dc.description.abstractAn experiment measuring the 2S Lamb shift in muonic hydrogen ([mu]-p) was performed at the Paul Scherrer Institute, Switzerland. It required small and compact detectors for 1.9 keV X-rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We chose Large Area Avalanche Photodiodes (LAAPDs) from Radiation Monitoring Devices as X-ray detectors, and they were used during the last data taking period in 2003. For X-ray spectroscopy applications, these LAAPDs have to be cooled in order to suppress the dark current noise; hence, a series of tests were performed to choose the optimal operation temperature. Specifically, the temperature dependence of gain, energy resolution, dark current, excess noise factor, and detector response linearity was studied. Finally, details of the LAAPDs application in the muonic hydrogen experiment as well as their response to [alpha] particles are presented.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6TJM-4F1S98H-4/1/06125e040d69c985c7b62cfe58fd372ben_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectLow-energy X-ray spectroscopyen_US
dc.subjectLarge Area Avalanche Photodiodes performanceen_US
dc.subjectTemperature dependenceen_US
dc.subjectResponse to [alpha] particlesen_US
dc.titlePlanar LAAPDs: temperature dependence, performance, and application in low-energy X-ray spectroscopyen_US
dc.typearticleen_US
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.researchunitLIP – Laboratory of Instrumentation and Experimental Particle Physics-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0001-7315-0550-
crisitem.author.orcid0000-0002-8832-8208-
crisitem.author.orcid0000-0003-4668-8958-
crisitem.author.orcid0000-0002-1912-2804-
crisitem.author.orcid0000-0002-8841-6523-
crisitem.author.orcid0000-0002-7107-7203-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
file79aabd0dbce94720b778fd7d1bb00899.pdf810.95 kBAdobe PDFView/Open
Show simple item record

Page view(s)

283
checked on Apr 10, 2024

Download(s)

330
checked on Apr 10, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.