Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/4403
DC FieldValueLanguage
dc.contributor.authorTávora, L. M. N.-
dc.contributor.authorDias, T. H. V. T.-
dc.contributor.authorConde, C. A. N.-
dc.date.accessioned2008-09-01T11:06:31Z-
dc.date.available2008-09-01T11:06:31Z-
dc.date.issued2006en_US
dc.identifier.citationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 562:1 (2006) 306-310en_US
dc.identifier.urihttps://hdl.handle.net/10316/4403-
dc.description.abstractThe effect of the presence of a drift electric field on the response of gaseous and semiconductor radiation detectors to energetic X-rays (energies from 20 to 200 keV) is investigated using the PENELOPE code to simulate the photo-absorption and the slow-down of the electrons produced in Si, Ge, and Xe gas at 1 atm. For typical drift fields, the energy deposited in the detection media is calculated taking into account the energy exchanged by the electrons with the field. The analysis of the calculated distributions shows that the effect of the field on the distributions is negligible in Si and Ge semiconductor detectors, but not in Xe gas detectors, where for the fluctuations introduced by the field for approach the intrinsic values for Xe, and the intrinsic discontinuity in linearity when crosses the Xe K-edge (34.56 keV) is further reduced by [approximate]4%. The simulation data also suggest that this field effect may cause some deviations to the expected Gaussian response of Xe detectors to the absorption of monoenergetic photons.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6TJM-4JKJSCP-3/1/3af24dda8150f1611ede9a26a32189f3en_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectGas detectorsen_US
dc.subjectSemiconductor detectorsen_US
dc.subjectX-ray and gamma-ray spectra distortionen_US
dc.subjectElectric-field effectsen_US
dc.subjectMonte Carlo simulationen_US
dc.titleA simulation study of the effect of drift electric fields on the response of radiation detectors using the PENELOPE codeen_US
dc.typearticleen_US
dc.identifier.doi10.1016/j.nima.2006.02.199-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
file4efd8eb7a9c74ba79a898f08e99459b5.pdf169.85 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

3
checked on Apr 22, 2024

WEB OF SCIENCETM
Citations

3
checked on Feb 2, 2024

Page view(s) 50

464
checked on Apr 23, 2024

Download(s) 50

454
checked on Apr 23, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.