dc.contributor.author | Veloso, J. F. C. A. | - |
dc.contributor.author | Amaro, F. D. | - |
dc.contributor.author | Azevedo, C. D. R. | - |
dc.contributor.author | Santos, J. M. F. dos | - |
dc.contributor.author | Breskin, A. | - |
dc.contributor.author | Lyashenko, A. | - |
dc.contributor.author | Chechik, R. | - |
dc.date.accessioned | 2008-09-01T11:05:34Z | - |
dc.date.available | 2008-09-01T11:05:34Z | - |
dc.date.issued | 2007 | en_US |
dc.identifier.citation | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 581:1-2 (2007) 261-264 | en_US |
dc.identifier.uri | https://hdl.handle.net/10316/4347 | - |
dc.description.abstract | We present the Photon-Assisted Cascaded Electron Multiplier (PACEM) as a potential alternative for ion back-flow suppression in gaseous cascade electron multipliers. Using a Micro Hole and Strip Plate-Gas Electron Multiplier (MHSP-GEM) configuration, the number of ions flowing back to the scintillation region is about 1.5 ions per primary electron at an optical gain of 6.5 and a drift field of 0.1 kV/cm, and about 10 ions per primary electron at an optical gain of 10 and a drift field of 0.5 kV/cm. These allow reaching ion back-flow values close to 10-4 and 10-5 at typical operation conditions of TPCs and GPMs, respectively. | en_US |
dc.description.uri | http://www.sciencedirect.com/science/article/B6TJM-4PB0PFX-15/1/9e6f704a6503d50bc4b54966701688c4 | en_US |
dc.format.mimetype | aplication/PDF | en |
dc.language.iso | eng | eng |
dc.rights | openAccess | eng |
dc.subject | Gaseous electron multipliers | en_US |
dc.subject | Gaseous photomultipliers | en_US |
dc.subject | VUV scintillation | en_US |
dc.subject | Photocathodes | en_US |
dc.title | PACEM: a new concept for high avalanche-ion blocking | en_US |
dc.type | article | en_US |
dc.identifier.doi | 10.1016/j.nima.2007.07.101 | - |
item.fulltext | Com Texto completo | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
item.openairetype | article | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
crisitem.author.researchunit | LIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics | - |
crisitem.author.researchunit | LIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics | - |
crisitem.author.parentresearchunit | University of Coimbra | - |
crisitem.author.parentresearchunit | University of Coimbra | - |
crisitem.author.orcid | 0000-0002-7107-7203 | - |
crisitem.author.orcid | 0000-0001-7315-0550 | - |
crisitem.author.orcid | 0000-0002-8841-6523 | - |
Appears in Collections: | FCTUC Física - Artigos em Revistas Internacionais |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
filebaa21dcf52bf44778a5d2d501e39b0b3.pdf | 442.24 kB | Adobe PDF | View/Open |
SCOPUSTM
Citations
6
checked on Nov 17, 2022
WEB OF SCIENCETM
Citations
5
checked on May 2, 2023
Page view(s)
315
checked on Oct 16, 2024
Download(s)
282
checked on Oct 16, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.