Title: | On the use of infrared thermography in studies with air curtain devices | Authors: | Neto, Luís P. C. Silva, M. C. Gameiro Costa, José J. |
Keywords: | Infrared thermography; Air curtains; Aerodynamic sealing; Whole-field measuring techniques | Issue Date: | 2006 | Citation: | Energy and Buildings. 38:10 (2006) 1194-1199 | Abstract: | Among the different existing methods to characterise the aerodynamic sealing effect provided by an air curtain device placed over the opening between two contiguous compartments, infrared thermography has revealed to be a very useful tool. Besides allowing the capture, in an expedite way, of instantaneous images of the temperature field in the neighbourhood of the door, the technique hereon described has other advantages, in terms of quick and easy setup, low intrusive character and liability of obtained results. | URI: | https://hdl.handle.net/10316/4220 | DOI: | 10.1016/j.enbuild.2006.02.004 | Rights: | openAccess |
Appears in Collections: | FCTUC Eng.Mecânica - Artigos em Revistas Internacionais |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
On the use of infrared thermography in studies with air curtain devices.pdf | 423.58 kB | Adobe PDF | View/Open |