Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/3965
Title: | Treatment of rising damp in historical buildings: wall base ventilation | Authors: | Torres, M. Isabel M. Peixoto de Freitas, Vasco |
Keywords: | Rising damp; Historical buildings; Hygrothermal properties; Wall base ventilation | Issue Date: | 2007 | Citation: | Building and Environment. 42:1 (2007) 424-435 | Abstract: | Intervention in older buildings increasingly requires extensive and objective knowledge of what one will be working with. The multifaceted aspect of work carried out on buildings tends to encompass a growing number of specialities, with marked emphasis on learning the causes of many of the problems that affect these buildings and the possible treatments that can solve them. Moisture transfer in walls of old buildings, which are in direct contact with the ground, leads to a migration of soluble salts responsible for many building pathologies. | URI: | https://hdl.handle.net/10316/3965 | Rights: | openAccess |
Appears in Collections: | FCTUC Eng.Civil - Artigos em Revistas Internacionais |