Title: Buckling length of a steel column for fire design
Authors: Gomes, Fernando C. T. 
Costa, Paulo M. Providência e 
Rodrigues, João Paulo C. 
Neves, Ildefonso C. 
Keywords: Buckling
Issue Date: 2007
Citation: Engineering Structures. 29:10 (2007) 2497-2502
Abstract: The Eurocode 3 part 1-2 gives some simple rules to determine the buckling length lfi of a steel column for fire design. In the case of a braced frame in which each storey comprises a separate fire compartment with sufficient fire resistance, Eurocode 3 suggests that the buckling length may be taken as lfi=0.5L in an intermediate storey and as lfi=0.7L in the top storey, where L is the system length in the relevant storey.
URI: https://hdl.handle.net/10316/3955
DOI: 10.1016/j.engstruct.2006.11.015