Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/12924
Title: Dual-Cathode CsI Covered Microstrip Plate as VUV High Efficiency Photosensor
Authors: Freitas, Diogo S. A. P. 
Silva, Rui M. Curado da 
Mendes, Nuno F. C. 
Conde, Carlos A. N. 
Keywords: Gaseous radiation detectors; Microstrip detectors; Photocathodes; X-ray spectroscopy detectors; Scintillation detectors
Issue Date: 8-Dec-2008
Publisher: IEEE
Citation: IEEE Transactions on Nuclear Science. 55:5 (2008) 2662-2665
Abstract: A Gas Proportional Scintillation Counter based on a dual-cathode Microstrip Plate covered with a CsI film is described. This new dual-cathode technique has the advantage of increasing the VUV sensitive area of the Microstrip Plate. A detailed description of the technique is presented together with a discussion of the performance. The results obtained for a xenon filled Gas Proportional Scintillation Counter show an improvement of the energy resolution for 5.9 keV X-rays from 12.7%, for a single cathode device, to 11.1% for the dual-cathode device
URI: https://hdl.handle.net/10316/12924
ISSN: 0018-9499
DOI: 10.1109/TNS.2008.2002325
Rights: openAccess
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais

Files in This Item:
File Description SizeFormat
Dual-Cathode CsI Covered Microstrip Plate.pdf1.13 MBAdobe PDFView/Open